ParodiJ.C., PalmezJ.C., BaroneH.D.Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg.1991; 5: 491–499.
2.
WainR.A., MarinM.L., OhkiT.Endoleaks after endovascular graft treatment of aortic aneurysms: classification, risk factors, and outcome. J Vasc Surg.1998; 27: 69–80.
3.
HeilbergerP., SchunnC., RitterW.Postoperative color flow duplex scanning in aortic endografting. J Endovasc Surg.1997; 4: 262–271.
4.
ZannettiS., DeRangoP., ParenteG.Role of duplex scan in endoleak detection after endoluminal abdominal aortic aneurysm repair. Eur J Endovasc Surg.2000; 19: 531–535.
5.
ParentF.N., MeierG.H., GodziachviliV.The incidence and natural history of type I and II endoleak: a 5-year follow-up assessment with color duplex ultrasound scan. J Vasc Surg.2002; 35: 474–481.
6.
PetrikP.V., MooreW.S.Endoleaks following aortic endovascular repair of abdominal aortic aneurysm: the predictive value of pre-operative anatomic factors- a review of 100 cases. J Vasc Surg.2001; 33: 739–744.
7.
WhiteG.H.Endoleak and endotension: definitions, classification and current concepts. In: VeithF.J., BaumR.A., eds. Endoleaks & Endotension: Current Consensus on their Nature and Significance.New York: Marcel Dekker; 2003: 25.
8.
SatoD.T., GoffC.D., GregoryR.T.Endoleak after aortic stent graft repair: diagnosis by color duplex ultrasound versus computed tomography scan. J Vasc Surg.1998; 28: 657–663.
9.
HeilbergerP., SchunnC., RitterW.Postoperative color flow duplex scanning in aortic endografting. J Endovasc Surg.1997; 4: 262–271.
10.
SprouseL.R., MeierG.H., Le sarC.J.Is ultrasound more accurate than axial computed tomography for determination of maximum abdominal aortic diameter?Euro J Vasc Endovasc Surg.2004; 28: 28–35.
11.
BertgesD.J., ChowK., WyersM.C.Abdominal aortic aneurysm size regression after endovascular repair is endograft dependent. J Vasc Surg.2003; 37: 716–723.
12.
AdiseshiahM.Sac exclusion, endopressure, and endotension following endovascular repair of abdominal aortic aneurysm: the role of sac volume measurement. In: VeithF.J., BaumR.A., eds. Endoleaks & Endotension: Current Consensus on their Nature and Significance.New York: Marcel Dekker; 2003: 249–254.
13.
NelmsC.R., CarterK.A., MeierG.H.A technique to improve the confidence of color duplex ultrasound assessment of aortic endografts: the use of contrast agents. J Vasc Ultrasound.2003; 27: 88–92.
14.
CarterK.A., NelmsC.R., BlochP.H.S.Doppler waveform assessment of endoleak following endovascular repair of abdominal aortic aneurysm: predictors of endoleak thrombosis. J Vasc Ultrasound.2000; 24: 119–122.
15.
ParentF.N., GodziachviliV., MeierG.H.Endograft limb occlusion and stenosis after ancure endovascular abdominal aneurysm repair. J Vasc Ultrasound.2002; 35: 686–690.