The excessive flow of arteriovenous fistulas is usually reduced by banding, plication or tapering of the inflow lumen with a suture or various external devices. However, these procedures are often associated with unpredictable outcomes. Presented here is an easy, safe and reliable method that deploys and constrains a stent graft in the inflow segment of the fistula in order to achieve long-lasting flow reduction.
ZanowJPetzoldKPetzoldMKruegerUScholzH. Flow reduction in high-flow arteriovenous access using intraoperative flow monitoring. J Vasc Surg. 2016;44(6):1273–1278.
2.
DemirDTosunAKahramanN, et al.Technique of circular narrowing with a polytetrafluoroethylene graft in patients with high-flow arteriovenous fistula: mid-term results. Acta Medica Mediterranea. 2017;33(4):587–591.
3.
SmithGEBarnesRGreenL, et al.A “Christmas Tree” band for the treatment of arteriovenous dialysis access–related steal syndrome. Ann Vasc Surg. 2013;27(2):239.e9–e12.
4.
TeixeiraGAlmeidaPSousaCN, et al.Arteriovenous access banding revisited. J Vasc Access. 2017;18(3):225–231.
5.
HastaogluIOTokozHOzgenA. An unusual complication following surgical banding procedure for steal syndrome: band migration and sudden arteriovenous fistula aneurysm formation. J Vasc Access. 2017;18(3):e31–e32.
6.
MalliosALucasJJenningsW. A mechanism of banding failure in excessively dilated fistulas. J Vasc Access. 2017; 19(1): 98–100.
7.
HongJH. A simple indispensable maneuver to prevent stent migration during deployment. J Vasc Access. 2017; 18(4): e52.
8.
HongJH. A percutaneous endovascular technique for reducing arteriovenous fistula flow. J Vasc Access2020;21(2):251–255.