Aneurysm models have been developed to study the pathobiology of abdominal aortic aneurysm and to evaluate the efficacy of endovascular therapy. The purpose of this review is to describe the use and limitations of current animal and experimental models for the characterization of endoleak following endovascular repair of abdominal aortic aneurysms.
Reilly JM , Tilson MDIncidence and etiology of abdominal aortic aneurysms . Surg Clin N Am. 1989;69: 705-711 .
2.
Melton L. , Bickerstaff L. , Hollier L. , et al. Changing incidence of abdominal aortic aneurysms. a population-based study . Am J Epidemiol.1984; 120: 379-386 .
3.
Lillienfeld D. , Gunderson P. , Sprafka J. , Vargas C.Epidemiology of aortic aneurysms: I. Mortality trends in the United States 1951-198 1. Atherosclerosis.1987;7: 637-643 .
4.
Szilagyi DE , Smith RF , DeRusso FJ , Elliott JP , Sherrin FWContribution of abdominal aortic aneurysmectomy to prolongation of life . Ann Surg.1966;164: 678-682 .
5.
National Center for Health Statistics.Vital Statistics of the United States, 1988. Vol 2: Mortality. Part A. Washington, DC: Government Printing Office ; 1991. DHS publication no. [PHS]: 91-11010.
6.
Gillum RFEpidemiology of aortic aneurysm in the United States . J Clin Epidemiol.1995;48: 1289-1294 .
7.
Ingoldby CJ , Wujanto R. , Mitchell JEImpact of vascular surgery on community mortality from ruptured aortic aneurysms . Br J Surg.1986;73: 551-553 .
8.
Johansson G. , Swedenborg J.Ruptured abdominal aortic aneurysms. a study of incidence and mortality . Br J Surg.1986 ;73: 101-103 .
9.
Bengtsson H. , Bergqvist D.Ruptured abdominal aortic aneurysm: a population-based study . J Vasc Surg.1993 ; 18: 74-78 .
10.
Ernst CBAbdominal aortic aneurysm . New Engl J Med.1993;328: 1167-1172 .
11.
Veith FJ , Goldsmith J. , Leather RP , Hannan ELThe need for quality assurance in vascular surgery . J Vasc Surg.1991;13: 523-526 .
12.
Katz DJ , Stanley JC , Zelenock GBOperative mortality rates for intact and ruptured abdominal aortic aneurysms in Michigan: an eleven-year statewide experience . J Vasc Surg.1994;19: 804-817 .
Marin ML , Veith FJ , Cyanamon J. , et al. Initial experience with transluminally placed endovascular grafts for the treatment of complex vascular lesions . Ann Surg.1995;222: 449-469 .
15.
Moore WSThe EVT tube and bifurcated endograft systems: technical considerations and clinical summary. EVI Investigators . J Endovasc Surg.1997 ;4: 182-194 .
16.
Zarins CK , White RA, Schwarten , et al. AneuRx stent graft versus open surgical repair of abdominal aortic aneurysms. multicenter prospective clinical trial . J Vasc Surg.1999;29: 292-308 .
Laborde JC , Parodi JC , Clem MF , et al. Intraluminal bypass of abdominal aortic aneurysms: feasibility study . Radiology. 1992;184: 185-190 .
19.
Mirich D. , Wright KC , Wallace S. , et al. Percutaneously placed endovascular grafts for aortic aneurysms: feasibility study . Radiology. 1989;170: 1033-1037 .
20.
Boudghene F. , Anidjar S. , Allaire E. , Osborne-Pellegrin M. , Bigot JM , Michel JBEndovascular grafting in elastase-induced experimental aortic aneurysms in dogs: feasibility and preliminary results . J Vasc Interv Radiol.1993;4: 497-504 .
21.
Wu MH , Shi Q. , Bhattacharya V. , Saubage LRDevelopment of a symmetric canine abdominal aortic aneurysm model with clinical relevance for endovascular graft studies . J Invest Surg.2001;14: 235-239 .
22.
Jordan WD Jr , Sampson LK , Iyer S. , et al. Abdominal aortic aneurysm repair via percutaneous endovascular stenting in the swine model . Am Surg.1998;206: 447-454 .
23.
Strindberg G. , Nichols P. , Ricci MA , et al. Experimental modification to a canine infrarenal aortic aneurysm model for the validation of endovascular stent grafts: an experimental study . J Invest Surg.1998;11 : 185-197 .
24.
Boudghene FP , Sapoval MR , Bonneau M. , LeBlanche AF , Lavaste FC , Michel JBAbdominal aortic aneurysm in sheep: prevention of rupture with endoluminal stent grafts . Radiology. 1998;206: 447-454 .
25.
Chuter TA , Viscomi S. , Slater JL , Nowygrod R. , Risberg B.Canine model of abdominal aortic aneurysm treated by endovascular graft implantation . Cardiovasc Surg.1997 ;5: 490-496 .
26.
Eton D. , Warner D. , Ownes C. , et al. Results of endoluminal grafting in an experimental aortic aneurysm model . J Vasc Surg.1996;23: 819-829 .
27.
Sanchez LA , Faries PL , Marin ML , et al. Chronic intraaneurysmal pressure measurement: an experimental method for evaluating the effectiveness of endovascular aortic aneurysm exclusion . J Vasc Surg.1997;26: 222-230 .
28.
Verbin C. , Donayre C. , Kopchok G. , Scoccianti M. , White RAAnterior patch aortic aneurysm model for the study of endoluminal grafts . J Invest Surg.1995;8: 381-388 .
29.
Criado E. , Marston WA , Woosley JT , et al. An aortic aneurysm model for the evaluation of endovascular exclusion prosthesis . J Vasc Surg.1995;22: 306-314 . Diaz S. , Uzieblo MR , Desai KM , et al. Type II endoleak in porcine model of abdominal aortic aneurysm . J Vasc Surg.2004;40: 339-344 .
30.
Ohki T. , Yadav J. , Gargiulo N. , et al. Preliminary results of an implantable wireless aneurysm pressure sensor in a canine model: will surveillance CT scan following endovascular AAA repair become obsolete?J Endovasc Ther. 2003;10(suppl): 320 .
31.
Dayal R. , Mousa A. , Bernheim J. , et al. Characterization of retrograde collateral (type II) endoleak using a new canine model . J Vasc Surg.2004 ;40: 985-994 .
32.
Dormer KJTransducer implantation . Med Electron.1980 ;11: 69-75 .
33.
Faries PL , Sanchez LA , Marin ML , et al. An experimental model for the acute and chronic evaluation of intraaneurysmal pressure . J Endovasc Surg.1997;4: 290-297 .
34.
Marty B. , Sanchez LA , Ohki T. , et al. Endoleak after endovascular graft repair of experimental aortic aneurysms: does coil embolization with angiographic “seal” lower intraaneurysmal pressure?J Vasc Surg.1998 ;27: 454-461 .
35.
Zarins CK , White RA , Schwarten D. , et al. AneuRx stent graft versus open surgical repair of abdominal aortic aneurysms: multicenter prospective clinical trial . J Vasc Surg.1999;29: 292-305 .
36.
Zarins CKAneuRx Clinical Investigators. The US AneuRx Clinical Trial: 6-year clinical update 2002 . J Vasc Surg.2003;37: 904-908 .
Greenberg RK , Lawrence-Brown M. , Bhandari G. , et al. An update of the Zenith endovascular graft for abdominal aortic aneurysms: initial implantation and mid-term follow-up data . J Vasc Surg.2001;33(suppl): S157-S164 .
39.
Matsumura JS , Katzen BT , Hollier LH , Dake MD :. Update on the bifurcated Excluder endoprosthesis: phase I results . J Vasc Surg.2001;33(suppl): S150-S153 .
40.
Criado FJ , Wilson EP , Fairman RM , Abul-Khoudoud O. , Wellons E.Update on the Talent aortic stent graft: a preliminary report from United States phase I and II trails . J Vasc Surg.2001;33(suppl): S146-S149 .
41.
Faries PL , Brener BJ , Connelly TL , et al. A multicenter experience with the Talent endovascular graft for the treatment of abdominal aortic aneurysms . J Vasc Surg.2002;35: 1123-1128 .
42.
White GH , Yu W. , May J.Endoleak: a proposed new terminology to describe incomplete aneurysm exclusion by an endoluminal graft . J Endovasc Surg.1996;3: 124-125 .
43.
White GH , Yu W. , May J. , Chaufour X. , Stephen MSEndoleak as a complication of endoluminal grafting of abdominal aortic aneurysm: classification, incidence, diagnosis, and management . J Endovasc Surg.1997;4: 152-168 .
44.
Veith FJ , Baum RA , Ohki T. , et al.Nature and significance of endoleaks and endotension: summary of opinions expressed at an international conference . J Vasc Surg.2002;35: 1029-1035 .
45.
Baum RA , Carpenter JP , Cope C. , et al. Aneurysm sac pressure measurements after endovascular repair of abdominal aortic aneurysms . J Vasc Surg.2001;33: 32-42 .
46.
van Marrewijk CJ , Buth J. , Harris PL , Norgren L. , Nevelsteen A. , Watt MGSignificance of endoleaks after endovascular repair of abdominal aortic aneurysms: the EUROSTAR experience . J Vasc Surg.2002;35: 461-473 .
47.
Sonesson B. , Dias N. , Malina M. , et al. Intra-aneurysmal pressure measurements in successfully excluded abdominal aortic aneurysm after endovascular repair . J Vasc Surg.2003;37: 733-738 .
48.
Chaer RA , Trocciola SM , Dayal R. , et al. Evaluation of a wireless pressure sensor in a canine model of retrograde-collateral (type II) endoleak . Presented at Surgical Forum, American College of Surgeons Meeting; October 16-20, 2005; San Francisco, CA.
49.
Milner R. , Ruurda JP , Blankensteijn JDDurability and validity of a remote, miniaturized pressure sensor in an animal model of abdominal aortic aneurysm . J Endovasc Ther. 2004;11: 372-377 .
50.
Timaran CH , Ohki T. , Veith FJ , et al. Influence of type II endoleak volume on aneurysm wall pressure and distribution in an experimental model . J Vasc Surg.2005;41: 657-663 .
51.
Chaudhuri A. , Ansdell LE , Grass AJ , Adiseshiah M.Intrasac pressure waveforms after endovascular aneurysm repair (EVAR) are a reliable marker of type I endoleaks, but not type II or combined types: an experimental study . Eur J Vasc Endovasc Surg.2002;28: 373-378 .
52.
Solis MM , Ayerdi J. , Babcock GA , et al. Mechanism of failure in the treatment of type II endoleak with percutaneous coil embolization . J Vasc Surg.2002;36: 485-491 .
53.
Walker SR , MacIerewicz J. , Hopkinson BRVascular surgical society of Great Britain and Ireland: prevention of lumbar artery endoleaks following endovascular abdominal aortic aneurysm repair with the selective use of absorbable gelatin sponge . Br J Surg.1999;86: 697 .
54.
Walker SR , MacIerewicz J. , Hopkinson BREndovascular AAA repair: prevention of side branch endoleaks with thrombogenic sponge . J Endovasc Surg.1999 ;6: 350-353 .
55.
Martin ML , Dolmatch BL , Fry PD , Machan LSTreatment of type II endoleaks with Onyx . J Vasc Interv Radiol.2001;12: 629-632 .
56.
Faries PL , Cadot H. , Agarwal H. , Kent KC , Hollier LH , Marin MLManagement of endoleaks after endovascular aneurysm repair: cuffs, coils and conversion . J Vasc Surg.2003;37: 1155-1161 .
57.
Rhee JY , Trocciola SM , Dayal R. , et al. Treatment of type II endoleaks with a novel polyurethane thrombogenic foam: induction of endoleak thrombosis and elimination of intra-aneurysmal pressure in the canine model . J Vasc Surg.2005;42: 321-328 .
58.
Hiraki T. , Pavcnik D. , Uchida BT , et al. Prophylactic residual aneurysmal sac embolization with expandable hydrogel embolic devices for endoleak prevention: preliminary study in dogs . Cardiovasc Intervent Radiol.2005;28: 459-466 .
59.
Schoder M. , Pavcnik D. , Uchida BT , et al. Small intestinal submucosa aneurysm sac embolization for endoleak prevention after abdominal aortic aneurysm endografting: a pilot study in sheep . J Vasc Interv Radiol.2004;15(1 Pt 1): 69-83 .
60.
Trocciola SM , Dayal R. , Chaer RA , et al. The development of endotension is associated with increased transmission of pressure and serous components in porous ePTFE stent grafts: characterization using a canine model . J Vasc Surg.2006. In press.
61.
Trocciola SM , Dayal R. , Lin Sc , et al. Intra-aneurysmal thrombus after stent graft treatment of abdominal aortic aneurysms: correlation of histology and MRI in a canine model . Presented at the Association of Academic Surgery 38th Annual Meeting ; November 11-13, 2004; Houston, TX.