KölbelTLeeTIvancevK, et al. In situ bending of a thoracic stent-graft: a proposed novel technique to improve thoracic endograft seal. J Endovasc Ther. 2008;15:62–66.
2.
FontanaFMacchiEPiacentinoF, et al. The evaluation of aortic diameter changes during long-term follow-up after endovascular treatment of acute blunt traumatic thoracic aortic injuries. Vasc Endovascular Surg. 2018;52:335–343.
3.
Marrocco-TrischittaMMSpampinatoBMazzeoG, et al. Impact of the bird-beak configuration on postoperative outcome after thoracic endovascular aortic repair: a meta-analysis. J Endovasc Ther. 2019;26(6):771–778.
4.
HsuHLChenCKChenPL, et al. The impact of bird-beak configuration on aortic remodeling of distal arch pathology after thoracic endovascular aortic repair with the Zenith Pro-Form TX2 thoracic endograft. J Vasc Surg. 2014;59:80–88.
5.
JonkerFHSchlosserFJGeirssonA, et al. Endograft collapse after thoracic endovascular aortic repair. J Endovasc Ther. 2010;17:725–734.
6.
RinaudoAMariaGScardullaF, et al. Biomechanical implications of excessive endograft protrusion into the aortic arch after thoracic endovascular repair. Comput Biol Med. 2015;66:235–241.
7.
KasirajanKDakeMDLumsdenA, et al. Incidence and outcomes after infolding or collapse of thoracic stent grafts. J Vasc Surg. 2012;55:652–658.
8.
UedaTFleischmannDDakeMD, et al. Incomplete endograft apposition to the aortic arch: bird-beak configuration increases risk of endoleak formation after thoracic endovascular aortic repair. Radiology. 2010;255:645–652.
9.
PastaSChoJSDurO, et al. Computer modeling for the prediction of thoracic aortic stent graft collapse. J Vasc Surg. 2013;57:1353–1361.
10.
CanaudLAlricPDesgrangesP, et al. Factors favoring stent-graft collapse after thoracic endovascular aortic repair. J Thorac Cardiovasc Surg. 2010;139:1153–1157.
11.
BoufiMGuivier-CurienCDeplanoV, et al. Risk factor analysis of bird beak occurrence after thoracic endovascular aortic repair. Eur J Vasc Endovasc Surg. 2015;50:37–43.
12.
PastaSScardullaFRinaudoA, et al. An in vitro phantom study on the role of the bird-beak configuration in endograft infolding in the aortic arch. J Endovasc Ther. 2016;23:172–181.
13.
ChengSWLamESFungGS, et al. A computational fluid dynamic study of stent graft remodeling after endovascular repair of thoracic aortic dissections. J Vasc Surg. 2008;48:303–309.
14.
LamSKFungGSChengSW, et al. A computational study on the biomechanical factors related to stent-graft models in the thoracic aorta. Med Biol Eng Comput. 2008;46:1129–1138.