The toxicity of 1, 2-Dichloroethane, DCE, toxicity was measured in an Electron-Microscopy (EM) preparation laboratory by Gas Chromatography. Although the personal exposure of the worker to DCE has not exceeded the occupational exposure limits, the exposure level was quite close to the short-term exposure limit. Owing to the carcinogenic potential and low exposure limits of DCE, it is suggested that a closed controlled-environment would be useful in reducing the exposure level of DCE.
Get full access to this article
View all access options for this article.
References
1.
Douglas, R.K. (1984). A method for producing dust-streak and hole-free Formvar films in laboratory having high atomspheric humidity. Stain Technology, 59 (1): 56-58.
2.
Health and Safety Executive (1988). Guidance Note EH 40/88 - Occupational Exposure Limits.
3.
National Institute for Occupational Safety and Health (NIOSH) (1977). Manual of Analytical Methods. 2: S110.1-S110.8 .