A physical compartmental model (INTAIR) has been pa rameterised to estimate PM10 concentrations and has been used to assess the contribution of smoking to PM10 levels for typical homes in the UK. The results suggest that smoking activity at home increases the daily mean concentrations in the living room by 1-1.5 μg.m-3 per cigarette smoked, and may contribute significantly to personal exposures to PM10. The model simulations demonstrate that the contribution of smoking to daily mean concentrations is highly dependent on the air exchange rate between the room and outdoors.
Pope CA, Dockery DW, Schwartz J.: Review of epidemiological evidence of health effects of particulate air pollution . Inhal Toxicol1995;7: 1-18.
2.
Anderson HR, Leon AP, de Bland JM, Bowe JS, Strachan DP: Air pollution and daily mortality in London: 1987-92. BMJ1996;312: 665-669.
3.
UK Parliament: House of Commons Environment Committee: Indoor Pollution, vol I. Report together with the Proceedings of the Committee relating to the Report, session 1990-91. Sixth Report. London, HMSO, 1991.
4.
Apeg: Airborne Particles Expert Group Report: Source apportionment of airborne particulate matter in the United Kingdom. London, Department of the Environment, Transport and the Regions, 1999.
5.
Wallace L.: Indoor particles: A review. JAir Waste Manag Assoc1996;46:98-126.
6.
Monn C., Fuchs A., Hogger D., Junker M., Kogelschatz D., Roth N., Wanner HU: Particulate matter less than 10 μm (PM10) and fine particle less than 2.5 μm (PM2.5): Relationships between indoor, outdoor, and personal concentrations. Sci Total Environ1997;208:15-21.
7.
Özkaynak H., Xue J., Spengler JD, Wallace LA, Pellizzari ED, Jenkins P.: Personal exposure to airborne particles and metals: Results from the particle TEAM study in Riverside, California. J Expo Anal Environ Epidemiol1996 ;6:57-78.
8.
Dimitroulopoulou C., Ashmore MR, Byrne MA, Kinnersley RP: Modelling of indoor exposure to nitrogen dioxide in the UK. Atmos Environ2001;35:269-279.
9.
Thatcher TL, Layton DW: Deposition, resuspension and penetration of particles within a residence . Atmos Environ1995;29:1487-1497.
10.
Byrne MA, Lange C., Goddard Ajh, Roed J.: Indoor aerosol deposition measurements for exposure assessment calculations; in Proc 6th Int Conf on Indoor Air Quality and Climate. Indoor Air1993;3:415-419.
11.
General Household Survey: Living in Britain. London, OPCS, 1994.
12.
NETCEN Web Site. Air Quality Archive- Automatic and Nonautomatic Monitoring Network Data. 1996:http://www.aeat.co.uk/ netcen/aqarchive/archome.html
13.
Koutrakis P. , Briggs Slk, Leaderer BP: Source apportionment of indoor aerosols in Suffolk and Onondaga Counties New York. Environ Sci Technol1992;23:521-527.