KadirS.WhiteR IKaufmanS L. Long-term results of aortoiliac angioplasty. Surgery1983; 94: 10–14.
2.
DotterC. T.Transluminally placed coil springs and arterial tube grafts: Long term patency in the canine popliteal artery. Invest Radiol1969; 4: 329–32.
CraggA.LundG.PysavyJ.CastenedaF.Castaneda-ZunigaW RAmplatzK.Nonsurgical placement of arterial endoprosthesis: A new technique using nitinol wire. Radiology1983; 147: 261–63.
7.
TominagaR.KambicH EEmotoH.HarasakiH.SuttonC.HollmanJ.Effects of design geometry of intravascular endoprostheses on stenosis rate in normal rabbits. Am Heart J1992; 123(1): 21–28.
8.
MaassD.ZollikoferChlLargiaderF.SenningA.Radiological follow up of transluminally inserted vascular endoprosthesis: An experimental study using expanded spirals. Radiology1984; 152: 659–63.
PalmazJ CKoppD THayashiH.. Normal and stenotic renal arteries: Experimental balloon expandable intraluminal stenting. Radiology1987; 164: 705–708.
12.
StreckerE PBergG.SchneiderB.FreudenburgN.WeberH.WolfR. D.A new vascular balloon expandable prosthesis: Experimental studies and first clinical results. J Interven Radiol1988; 3: 59–62.
13.
SuttonC SOkuT.HarasakiH.. Titanium-nickel intravascular endoprosthesis. Am J Roentgenol1988; 151: 597–601.
14.
SuttonC STominagaR.HarasakiH.. Vascular stenting in normal and atherosclerotic rabbits. Studies of the intravascular endoprosthesis of titanium nickel alloy. Circulation1990; 81: 667–83.
SigwartU.PuelJ.MirkovitchV.JoffreF.KappenbergerL.Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty. N Engl J Med1987; 316: 701–706.
17.
RousseauH.JoffreF.RaillatC.. Self expanding endovascular stent in experimental atherosclerosis: Work in progress. Radiology1989; 170(3Pt 1): 773–78.
18.
RoubinG SRobinsonK AKingS B. Early and late results of intracoronary arterial stenting after coronary angioplasty in dogs. Circulation1987; 76: 891–97.
19.
RobinsonK ARoubinG SSiegalR JBlackA JApkarianR PKingS B3rd. Intra-arterial stenting in the atherosclerotic rabbit. Circulation1988; 78: 646–53.
20.
DupratG.JrWrightK CCharansangavejC.WallaceS.GianturcoC.Self expanding metallic stents for small vessels: An experimental evaluation. Radiology1987; 162: 469–72.
21.
RodgersG PMinorS TRobinsonK.. The coronary artery response to implantation of a balloon-expandable flexible stent in the aspirin- and non-aspirin-treated swine model. Am Heart J1991; 122(3 Pt 1): 640–47.
22.
YoshiokaT.WrightK CWallaceS.LawrenceD DJrGianturcaC.Self expanding endovascular graft: An experimental study in dogs. Am J Roentgenol1988; 151: 673–76.
PalmazJ CKoppD THayashiH.. Normal and stenotic renal arteries: Experimental balloon expandable intraluminal stenting. Radiology1987; 164: 705–708.
27.
SchatzR APalmazJ.TioF O. Balloon expandable intracoronary stents in the adult dog. Circulation1987; 76: 450–57.
28.
SchatzR. A.Introduction to intravascular stents. Cardiol Clin1988; 6: 357–72.
29.
BarthK HVirmaniR.StreckerE P. Flexible tantalum stents implanted in aortas and iliac arteries: Effects in normal canines. Radiology1990; 175: 91–96.
30.
StreckerE PLiermannD.BarthK H. Expandable tubular stents for treatment of arterial occlusive diseases: Experimental and clinical results. Radiology1990; 175: 97–102.
31.
CarabasiR AWilliamsS KJarrellB. E.Cultured and immediately procured endothelial cells: Current and future clinical applications. Ann Vasc Surg1991; vmr-5(5): 477–84.
32.
FlugelmanM YVirmaniR.LeonM BBowmanR LDichekD. A.Genetically engineered endothelial cells remain adherent and viable after stent deployment and exposure to flowin vitro. Circ Res1992; 70(2): 348–54.
33.
Van der GiessesW JSerruysP WVisserW JVerdouwP DVan SchalkwijkW PJonkindJ. F.Endothelialisation of intravascular stents. J Interven Cardiol1988; 1: 2.
34.
AgrawalC MHaasK FLeopoldD AClarkH. G.Evaluation of poly(L-lactic acid) as a material for intravascular polymeric stents. Biomaterials1992; 13(3): 176–82.
35.
PalmazJ CRichterG MNoldgeG.KauffmannG WWenzW.Die intraluminale Stent-Implantation nach Palmaz. Erster klinischer Fallbericht uber eine ballonexpandierte Gefassprothese. Radiologe1987; 27(12): 560–63.
36.
RichterG MNoldgeG.PalmazJ CTioF.Generalisierte Arteriosklerose und Stentimplantation. Ein epikritischer Bericht. Radiologe1991; 31(3): 114–49.
37.
PalmazJ CRichterG MNoeldgeG.. Intraluminal stents in atherosclerotic iliac artery stenosis: Preliminary report of a multicenter study. Radiology1988; 168: 727–31.
38.
ReesC RPalmazJ CGarciaO.. Angioplasty and stenting of completely occluded iliac arteries. Radiology1989; 172(3 Pt 2): 953–59.
39.
CikritD FBeckerG JDalsingM CEhrmanK OLalkaS GSawchukA. P.Early experience with the Palmaz expandable intraluminal stent in iliac artery stenosis. Ann Vasc Surg1991; vmr-5(2): 150–55.
40.
Gross-FengelsW.FriedmannG.PalmazJ. C.Ballonexpandierbare Stents bei arteriellen Veranderungen der Beckenstrombahn. Fruh- und Nachuntersuchungsergebnisse von 65 Interventionen. ROFO1991; 155(4): 349–56.
41.
SoulenM CBonnJ.ShapiroM. J.Recanalization of an occluded aortoiliac bypass graft with Palmaz stents. J Vasc Interven Radiol1991; 2(4): 497–501.
42.
PalmazJ CEncarnacionC EGarciaO J. Aortic bifurcation stenosis: Treatment with intravascular stents. J Vasc Interven Radiol1991; 2(3): 319–23.
43.
GuntherR WVorwerkD.BohndorfK.El-DinA.PetersI.MessmerB. J.Perkutane Implantation von Gefassendoprothesen (Stents) in Becken- und Oberschenkelarterien. Dtsch Med Wochenschr1989; 114(40): 1517–23.
44.
TrillerJ.MahlerF.DoD.ThalmannR.Die vaskulare Endoprothese bei femoropoplitealer Verschlusskrankheit. ROFO1989; 150(3): 328–34.
45.
VorwerkD.GuentherR. W.Mechanical revascularization of occluded iliac arteries with use of self-expandable endoprostheses. Radiology1989; 175(2): 411–15.
46.
RaillatC.RousseauH.JoffreF.RouxD.Treatment of iliac artery stenosis with the Wallstent endoprosthesis. Am J Roentgenol1990; 154(3): 613–16.
47.
BucxJ JDe ScheerderI.BeattK.. The importance of adequate anticoagulation to prevent early thrombosis after stenting of stenosed venous by-pass grafts. Am J Heart J1991; 121(5): 1389–96.
48.
BreckwoldtW LBelkinM.GouldK.AllenM.ConnollyR JTerminP.Modification of the thombogenicity of a self-expanding vascular stent. J Invest Surg1991; 4(3): 269–78.
49.
ZollikoferC LAntonucciF.PfyfferM.. Arterial stent placement with use of the Wallstent: Midterm results of clinical experience. Radiology1991; 179(2): 449–56.
50.
ZochollG.ZapfS.SchildH.ThelenM.Funktionsangiographie der kniegelenknahen Arterien: Konsequenzen fur die Stentimplantation?ROFO1990; 153(6): 658–62.
51.
WilmsG EPeeneP TBaertA L. Renal artery stent placement with use of the Wallstent endoprosthesis. Radiology1991; 179(2): 457–62.
52.
KichikawaK.YoshiokaT.NishimineK.KubotaY.OhishiH.UchidaH.Treatment with expandable metallic stent for arterial occlusive disease. Nippon Igaku Hoshasen Gakkai Zasshi1989; 49(11): 1433–35.
53.
KichikawaK.UchidaH.YoshiokaT.. Iliac artery stenosis and occlusion: Preliminary results of treatment with Gianturco expandable metallic stents. Radiology1990; 177(3): 799–802.
54.
CharnsangavejC.WallaceS.WrightK CCarrascoC HGianturcoC.Endovascular stent for use in aortic dissection: An in vitro experiment. Radiology1985; 157(2): 323–24.
55.
SawadaS.FujiwaraY.KoyamaT.. Self-expandable metallic stent for use in arterial occlusive lesions. Nippon Igaku Hoshasen Gakkai Zasshi1991; 51(1): 9–18.
56.
Gross-FengelsW.FriedmannG.FischbachR.ErasmiH.BullingB.Stents bei iliakalen Gefassveranderungen. Vasa1991; 33 (suppl): 187–86.
57.
LongA LPageP ERaynaudA C. Percutaneous iliac artery stent: Angiographic long-term follow-up. Radiology1991; 180(3): 771–78.
58.
GuntherR WVorwerkD.Indikationen zur Implantation von vaskularen Endoprothesen (Stents). Radiologe1991; 31(3): 108–13.
59.
KuhnF PKutkuhnB.TorselloG.ModderU.Renal artery stenosis: Preliminary results of treatment with the Strecker stent. Radiology1991; 180(2): 367–72.
60.
ZollikoferC LLargiaderI.BruhlmannW FUhlschmidG KMartyA. H.Endovascular stenting of veins and grafts: Preliminary clinical experience. Radiology1988; 167: 707–12.
61.
GuntherR WVorwerkD.BohndorfK.. Venous stenoses in dialysis shunts: Treatment with self-expanding metallic shunts. Radiology1989; 170(2): 401–405.
62.
GlanzS.GordonD HButtK M HHongJ.LipkowitzG. S.The role of percutaneous angioplasty in the management of chronic haemodialysis fistulas. Ann Surg1987; 206: 777–81.
63.
AntonucciF.SalomonowitzE.StuckmannG.StiefelM.LargiaderJ.ZollikoferC. L.Placement of venous stents: Clinical experience with a self-expanding prosthesis. Radiology1992; 183(2): 493–97.
64.
LandwehrP.LacknerK.GotzR.Dilatation und ballonexpandierbare Stents zur Therapie zentralvenoser Stenosen bei Dialysepatienten. ROFO1990; 153(3): 239–45.
65.
BeathardG. A.The use of the Gianturco intravascular stent in stenotic hemodialysis fistulas. ASAIO Trans1991; 37(3): M234–M235.
66.
QuinnS FSchumanE SHallL.. Venous stenoses in patients who undergo hemodialysis: Treatment with self-expandable endovascular stents. Radiology1992; 183(2): 499–504.
67.
ChansangavejC.CarasacoC HWallaceS.. Stenosis of the vena cava: Preliminary assessment of treatment with expandable metallic stents. Radiology1986; 161: 295–98.
68.
FuruiS.SawadaS.IrieT.. Hepatic inferior vena cava obstruction: Treatment of two types with Gianturco expandable metallic stents. Radiology1990; 176(3): 665–70.
69.
LopezR RJrBennerK GHallL.RoschJ.PinsonC. W.Expandable venous stents for treatment of the Budd–Chiari syndrome. Gastroenterology1991; 100(5 Pt 1): 1435–41.
70.
CarrascoC HCharnsangavejC.WrightK CWallaceS.GianturcoC.Use of the Gianturco self-expanding stent in stenoses of the superior and inferior venae cavae. J Vasc Interven Radiol1992; 3(2): 409–19.
71.
ElsonJ DBeckerG JWholeyM HEhrmanK. O.Vena caval and central venous stenoses: Management with Palmaz balloon-expandable intraluminal stents. J Vasc Interven Radiol1991; 2(2): 215–23.
72.
DeviereJ.DelcourC.SalameM.. Shunt intrahepatique par voie transjugulaire en urgence. Acta Gastroenterol Belg1992; 55(1): 11–16.
73.
BeckA.ReinboldW DBlumU.NankoN.MilicS.PapacharalampousX.Clinical application of percutaneous transluminal angioscopy. Comparison of findings in percutaneous angioplasty, thrombolysis, thrombus-extraction and stent-application. Herz1988; 13(6): 392–99.
74.
IsnerJ MRosenfieldK.LosordoD W. Percutaneous intravascular US as adjunct to catheter-based interventions: Preliminary experience in patients with peripheral vascular disease. Radiology1990; 15(1): 61–70.
75.
SlepianM. J.Application of intraluminal ultrasound imaging to vascular stenting. Int Cardiol Imaging1991; 6(3–4): 285–311.
76.
Di SegniR.EngelerC.LetourneauJ G. L'ecografia intravascolare nella radiologia interventistica arteriosa. Radiol Med1991; 82(4): 484–92.
77.
CavayeD MTabbaraM RKopchokG ETerminP.WhiteR. A.Intraluminal ultrasound assessment of vascular stent deployment. Ann Vasc Surg1991; vmr-5(3): 241–46.
78.
VorwerkD.GuentherR WGehlH BBohndorfK.Color-coded image-directed Doppler sonography compared with digital subtraction angiography in the follow-up of percutaneous vascular endoprostheses. J Clin Ultrasound1990; 18(8): 631–37.
79.
BergeronP.RudondyP.PoyenV.PinotJ JAlessandriC.MarteletJ. P.Long-term peripheral stent evaluation using angioscopy. Int Angiol1991; 10(3): 182–86.
RoubinG SRobinsonK AKingS B. Early and late results of intracoronary arterial stenting after coronary angioplasty in dogs. Circulation1987; 76: 891–97.
84.
SerruysP WJuilliereY.BertrandM EPuelJ.RickardsA FSigwartU.Additional improvement of stenosis geometry in human coronary arteries by stenting after balloon dilatation. Am J Cardiol1988; 61: 71G–76G.
85.
De ScheerderI KStraussB HDe FeyterP J: Stenting of venous bypass grafts: A new treatment modality for patients who are poor candidates for reintervention. Am Heart J1992; 123(4 Pt 1): 1046–54.
86.
BucxJ JDe ScheerderI.BeattK.. The importance of adequate anticoagulation to prevent early thrombosis after stenting of stenosed venous bypass grafts. Am Heart J1991; 121(5): 1389–96.
87.
BajajR KRoubinG. S.Intravascular stenting of the right internal mammary artery. Catheter Cardiovasc Diagn1991; 24(4): 252–55.
88.
AlmagorY.ThomasJ.ColomboA.Balloon expandable stent implantation of a stenosis at the origin of the left internal mammary artery graft: A case report. Catheter Cardiovasc Diagn1991; 24(4): 256–58.
89.
MullerD WEllisS GDeboweyD LTopolE. J.Quantitative angiographic comparison of the immediate success of coronary angioplasty, coronary atherectomy and endoluminal stenting. Am J Cardiol1990; 66: 938–42.
90.
GoyJ JSigwartU.VogtP.. Long-term follow-up of the first 56 patients treated with intracoronary self-expanding stents (the Lausanne experience). Am J Cardiol1991; 67: 569–72.
91.
MullerD WShamirK JEllisS GTopolE. J.Peripheral vascular complications after conventional and complex percutaneous coronary interventional procedures. Am J Cardiol1992; 69(1): 63–68.
92.
RabS TKingS B3rdRoubinG SCarlinS.HearnJ ADouglasJ SJr. Coronary aneurysms after stent placement: A suggestion of altered vessel wall healing in the presence of anti-inflammatory agents. J Am Coll Cardiol1991; 18(6): 1524–28.
93.
SerruysP WStraussB HBeattK J. Angiographic follow-up after placement of a self-expanding coronary-artery stent. N Engl J Med1991; 324: 13–17.
94.
MooreJ WKirbyW CLovettE JO'NeillJ. T.Use of an intravascular endoprosthesis (stent) to establish and maintain short-term patency of the ductus arteriosus in newborn lambs. Cardiovasc Interven Radiol1991; 14(5): 299–301.
95.
CoeJ YOlleyP. M.A novel method to maintain ductus arteriosus patency. J Am Coll Cardiol1991; 18(3): 837–41.
96.
GibbsJ LRothmanM TReesM RParsonsJ MBlackburnM ERuizC. E.Stenting of the arterial duct: A new approach to palliation for pulmonary atresia. Br Heart J1992; 67(3): 240–45.
97.
BensonL NHamiltonF.DasmahapatraH.RabinowitchM.ColesJ CFreedomR. M.Percutaneous implantation of a balloon-expandable endoprosthesis for pulmonary artery stenosis: An experimental study. J Am Coll Cardiol1991; 18(5): 1303–308.
98.
HoskingM CBensonL NNakanishiT.BurrowsP EWilliamsW GFreedomR. M.Intravascular stent prosthesis for right ventricular outflow obstruction. J Am Coll Cardiol1992; 20(2): 373–80.
99.
EllisSgRoubinG SKingS B. Intracoronary stenting to prevent restenosis: Preliminary results of a multicenter study using the Palmaz–Schatz stent suggest benefit in selected high risk patients [Abstract]. J Am Coll Cardiol1990; 15: 118A.
100.
BucxJ JDe ScheerderI.BeattK.. The importance of adequate anticoagulation to prevent early thrombosis after stenting of stenosed venous by-pass grafts. Am Heart J1991; 121: 1389–96.
101.
FischellT AStadiusM. L.New technologies for the treatment of obstructive arterial disease. Catheter Cardiovasc Diagn1991; 22(3): 205–33.