Restenosis remains the bane of percutaneous coronary intervention. Local delivery of radiation, brachytherapy, is a promising therapy for the prevention of restenosis. Animal studies have suggested that brachytherapy may be an effective treatment for preventing restenosis. The type of radiation as well as the doses and delivery systems are currently under study; several clinical trials are underway. This paper reviews the biological basis, including animal studies, of intracoronary brachytherapy as well as the current data from clinical trials.
Kivalic JJ and Perez CA.Radiation therapy after keloidectomy: a 20 year experience. Int J Radiat Oncol Biol Phys1989; 17: 77-80.
2.
MacLennan I, Keys HM, Evarts CM, Rubin P.Usefulness of post operative hip irradiation in the prevention of heterotopic bone formation in a high risk group of patients. Int J Radiat Oncol Biol Phys1984; 10: 49-53.
3.
Wilder RB, Buatt JM, Kittleson JMet al.Pterygium treated with excision and post-operative beta irradiation. Int J Radiat Oncol Biol Phys1992; 23: 533-537.
4.
Donaldson SS, Bagshaw MA, Kriss JP.Supervoltage orbital radiotherapy for Graves’ ophthalmopathy. J Clin Endocrinol Metab1973; 37: 276-285.
5.
Gagnon JD, Moss WT, Stevens KR.Pre-estrogen breast irradiation for patients with carcinoma of the prostate: a critical review. J Urol1979; 121: 182-184.
6.
Kjellberg RN, Hanamura T, Davis KR, Lyons SL, Adams RD.Bragg-peak proton-beam therapy for arteriovenous malformations of the brain. N Engl J Med1983; 309: 269-274.
7.
Brenner DJ, Miller RC, Hall EJ.The radiobiology of intravascular irradiation. Int J Radiat Oncol Biol Phys1996; 36: 805-810.
8.
Teirstein PS, Massullo V, Jani Set al.Catheter-based radiotherapy to inhibit restenosis after coronary stenting. N Engl J Med1997; 336: 1697-1703.
9.
Mazur W, Ali MN, Khan MMet al.High dose rate intracoronary radiation for inhibition of neointimal formation in the stented and balloon-injured porcine models of restenosis: angiographic, morpho-metric, and histopathologic analyses. Int J Radiat Oncol Biol Phys1996; 36: 777-788.
10.
Weinberger J, Amols H, Ennis RD, Schwartz A, Wiedermann JG, Marboe C.Intracoronary irradiation: dose response for the prevention of restenosis in swine. Int J Radiat Oncol Biol Phys1996; 36: 767-775.
11.
Bole PV, Hintz G, Chander P, Chan YS, Clauss RH.Bilateral carotid aneurysms secondary to radiation therapy. Ann Surg1975; 181: 888-892.
12.
Austin GE, Ratliff NB, Hollman J, Tabei S, Philip DF.Intimal proliferation of smooth muscle cells as an explanation for recurrent coronary artery stenosis after percutaneous transluminal coronary angioplasty. J Am Coll Cardiol1985; 6: 369-375.
13.
Liu MW, Roubin GS, King SB III.Restenosis after coronary angioplasty: potential biologic determinants and role of intimal hyperplasia. Circulation1989; 79: 1374-1387.
14.
Karas SP, Gravanis MB, Santoian EC, Robinson KA, Anernerg KA, King SB III.Coronary intimal proliferation after balloon injury and stenting in swine: an animal model of restenosis. J Am Coll Cardiol1991; 20: 467-474.
15.
Popowski Y, Verin V, Papirov Iet al.High dose rate brachytherapy for prevention of restenosis after percutaneous transluminal coronary angioplasty: preliminary dosimetric tests of a new source presentation. Int J Radiat Oncol Biol Phys1995; 33: 211-215.
16.
Abbas MA, Afshari NA, Stadius ML, Kernoff RS, Fischell TA.External beam irradiation inhibits neointimal hyperplasia following balloon angioplasty. Int J Cardiol1994; 44: 191-202.
17.
Schwartz RS, Koval TM, Edwards WDet al.Effect of external beam irradiation on neointimal hyperplasia after experimental coronary artery injury. J Am Coll Cardiol1995; 19: 1106-1113.
18.
Wiedermann JG, Marboe C, Amols H, Schwartz A, Weinberger J.Intracoronary irradiation markedly reduces restenosis after balloon angioplasty in a porcine model. J Am Coll Cardiol1994; 23: 1491-1498.
19.
Wiedermann JG, Marboe C, Amols H, Schwartz A, Weinberger J.Intracoronary irradiation markedly reduces neointimal proliferation after balloon angioplasty in swine: persistent benefit at 6-month follow-up. J Am Coll Cardiol1994; 25: 1451-1456.
20.
Waksman R, Robinson KA, Crocker IR, Gravanis MB, Cipolla GD, King SB.Endovascular low-dose irradiation inhibits neointimal formation after coronary artery balloon injury in swine: a possible role for radiation therapy in restenosis prevention. Circulation1995; 91: 1533-1539.
21.
Verin V, Popowski Y, Urban Pet al.Intra-arterial beta-irradiation prevents neointimal hyperplasia in a hypercholesterolemic rabbit restenosis model. Circulation1995; 92: 2284-2290.
22.
Wilcox JN, Waksman R, King SB, Scott NA.The role of the adventitia in the arterial response to angioplasty: the effect of intravascular radiation. Int J Radiat Oncol Biol Phys1996; 36: 789-796.
23.
Makkar R, Whiting J, Li Aet al.A b-emitting liquid isotope filled balloon markedly inhibits restenosis in stented porcine coronary arteries. J Am Coll Cardiol1998; 31: 350A-350A.
24.
Kim H-S, Cho Y-H, Kim J-Set al.Effect of transcatheter endovascular holmium-166 irradiation on neointimal formation after balloon injury in porcine coronary artery. J Am Coll Cardiol1998; 31: 277A-277A.
25.
Waksman R, Chan RC, Vodovotz Y, Bass BG, Apple MG.Radioactive 133-xenon gas-filled angioplasty balloon: a novel intracoronary radiation system to prevent restenosis. J Am Coll Cardiol1998; 31: 356A-356A.
26.
Waksman R, Saucedo JF, Chan RC, Kim WH, Vodovotz Y, Verin V.Yttrium-90 delivered via a centering catheter and remote afterloader, uniformly inhibits neointima formation after balloon injury or stenting in swine coronary arteries. J Am Coll Cardiol1998; 31: 278A-278A.
27.
Waksman R, Robinson KA, Crocker IRet al.Intracoronary radiation before stent implantation inhibits neointima formation in stented porcine coronary arteries. Circulation1995; 92: 1383-1386.
28.
Fischell TA, Kharma BK, Fischell DRet al.Low-dose, b-particle emission from ‘stent’ wire results in complete localized inhibition of smooth muscle cell proliferation. Circulation1994; 90: 2956-2963.
29.
Hehrlein C, Gollan C, Dönges Ket al.Low-dose radioactive endovascular stents prevent smooth muscle cell proliferation and neointimal hyperplasia in rabbits. Circulation1995; 92: 1570-1575.
30.
Hehrlein C, Stintz M, Kinschref Ret al.Pure b-particle-emitting stents inhibit neointima formation in rabbits. Circulation1996; 93: 641-645.
31.
Laird JR, Carter AJ, Kufs WMet al.Inhibition of neointimal proliferation with low-dose irradiation from a b-particle-emitting stent. Circulation1996; 93: 529-536.
32.
Carter AJ, Laird JR, Bailey LRet al.Effects of endovascular radiation from a b-particle-emitting stent in a porcine coronary restenosis model: a dose-response study. Circulation1996; 94: 2364-2368.
33.
Rivard A, Leclerc G, Bouchard Met al.Low-dose b-emitting radioactive stents inhibit neointimal hyperplasia in porcine coronary arteries: an histological assessment. J Am Coll Cardiol1997; 29: 238A-238A.
34.
Shimotokara S, Mayberg MR.Gamma irradiation inhibits neointimal hyperplasia in rats after arterial injury. Stroke1994; 25: 424-428.
35.
Weinberger J, Mirzadeh S, Knapp FFR, Amols H.Beta irradiation for restenosis after stent implantation: dose variations among differing stents. J Am Coll Cardiol1997; 29: 238A-238A.
36.
Steidle B.Preventive percutaneous radiotherapy for avoiding hyper-plasia of the intima following angioplasty together with stent implantation. Strahlenther Onkol1994; 170: 150-154.
37.
Liermann DD, Boettcher HD, Kollateh Jet al.Prophylactic endovascular radiotherapy to prevent intimal hyperplasia after stent implantation in femoropopliteal arteries. Cardiovasc Intervent Radiol1994; 17: 12-16.
38.
Waksman R, Crocker IR, Kikeri Det al.Endovascular low-dose radiation for the prevention of restenosis following angioplasty for treatment of narrowed dialysis arteriovenous grafts. J Am Coll Cardiol1996; 27: 14A-14A.
39.
Condado JA, Waksman R, Gurdiel Oet al.Long-term angiographic and clinical outcome after percutaneous transluminal coronary angioplasty and intracoronary radiation in humans. Circulation1997; 96: 727-732.
40.
Condado JA, Saucedo JF, Caldera Cet al.Two year angiographic evaluation after intracoronary 192 Iridium in humans. Circulation1997; 96: I 220-I 220
41.
Teirstein PS, Massullo V, Jani Set al.Initial report of gamma radio-therapy for diffuse coronary restenosis: the SCRIPPS II trials. JAm Coll Cardiol1998; 31: 238A-238A.
42.
Waksman R, White RL, Chan RCet al.Intracoronary radiation therapy for patients with in-stent restenosis. Interim report from a randomized clinical study. J Am Coll Cardiol1998; 31: 222A-222A.
43.
Verin V, Urban P, Popowski Yet al.Feasibility of intracoronary b-irradiation to reduce restenosis after balloon angioplasty. A clinical pilot study. Circulation1997; 95: 1138-1144.
44.
Baim DS, Fischell T, Weissman NJ, Laird JR, Marble SJ, Kalon KH.Short-term (1 month) results of the IRIS feasibility study of a beta-particle emitting radioisotope stent. Circulation1997; 96: I-218-I-218.
45.
Moses JW, Ellis SG, Bailey SRet al.Short-term (1 month) results of the dose response IRIS feasibility study of a beta-particle emitting radioisotope stent. J Am Coll Cardiol1998; 31: 350A-350A.
46.
King III SB, Williams DO, Chougule Pet al.Endovascular b-radiation to reduce restenosis after balloon angioplasty: results of the beta energy restenosis trial (BERT). Circulation1998; 97: 2025-2030.
47.
Meerkin D, Bonan R, Bertrand O, Vincent J, Paiement P, Tardif J-C.Radiation effects on dissection resolution: an IVUS study. Presented at Cardiovascular Radiation Therapy III, Washington DC, February 17-19, 1999. Abstract 48, p. 23-23.
48.
Lee DP, Lo S, Forster KF, Tate DJ, Raizner A, Oesterle SN.Intracoronary radiation with a 32P source wire. Herz1998; 23: 362-365.
49.
Raizner AE, Oesterle S, Waksman Ret al.The PREVENT Trial, a feasibility study of intracoronary brachytherapy in the prevention of restenosis: an interim report. Circulation1998; 98: I-651-I-651.
50.
Gottdiener JS, Katin MJ, Borer JS, Bacharach SL, Green MV.Late cardiac effects of therapeutic mediastinal irradiation: assessment by echocardiography and radionuclide angiography. N Engl J Med1983; 308: 569-572.
51.
Iqbal SM, Hanson EL, Gensini GG.Bypass graft for coronary arterial stenosis following radiation therapy. Chest1977; 71: 664-666.
52.
Waksman R.Stents and restenosis. Oral presentation at the 1998 American College of Cardiology Scientific Meeting, Atlanta, GA.
53.
Mews GC, Fox R, Cope G, Clugston R, Cumpston GN, Gibbons F.Re-188 liquid filled balloon for the treatment of intracoronary instent restenosis. Presented at Cardiovascular Radiation Therapy III, Washington DC, February 17-19, 1999. Abstract 7, p. 64-64.
54.
Arbab-Zabeh A, Russo RJ, Jani SKet al.A comparison of centered vs non-centered source for intracoronary radiation therapy: observations from the SCRIPPS trial. Circulation1997; 96: I-219-I-219.
55.
Crilly RJ, Roberts W, Spears JR.Perturbations in radiation fields due to calcification for isotopes considered for intravascular brachytherapy. Circulation1997; 96: I-15-I-15.
56.
Honda H, Hausleiter J, Li A, Makkar R, Whiting J, Eigler N.Edge stenosis after ‘low dose’ radiation therapy using a Re188 liquid-filled balloon system. Presented at Cardiovascular Radiation Therapy III, Washington DC, February 17-19, 1999. Abstract 14, p. 30-30.
57.
Serruys PW, Levendag PC.Intracoronary brachytherapy: the death knell of restenosis or just another episode of a never-ending story?Circulation1997; 96: 709-712.