Abstract
Background:
Detecting cortical demyelination using magnetic resonance imaging (MRI) in multiple sclerosis (MS) remains a challenge. Magnetization transfer ratio (MTR), T1-weighted/T2-weighted ratio (T1T2R), and T2-weighted (T2w) signal are sensitive to cortical demyelination, but their accuracy is unknown.
Objectives:
To quantify the sensitivity, specificity, and accuracy of postmortem T1T2R, MTR, and T2w in detecting cortical demyelination.
Methods:
In situ postmortem MRIs from 9 patients were used to measure T1T2R, MTR, and T2w along the midline of cortical gray matter and classified as normal or abnormal. MRIs were co-registered and compared to hemispheric myelin staining. The sensitivity, specificity, and accuracy of T1T2R, MTR, and T2w in detecting cortical demyelination were measured.
Results:
The mean age (standard deviation) at death was 64.7 (+/-13.7) years with a disease duration of 23.8 (+/-10.5) years. The sensitivity was 78% for MTR, 75% for T1T2R, and 63% for T2w. The specificity was 46% (T2w), 13% (T1T2R), and 29% (MTR). The accuracy was 71% (T2w), 39% (MTR), and 42% (T1T2R). There were no significant differences between different MRI measures in cortical demyelination or intracortical/subpial lesion detection.
Conclusions:
Although somewhat sensitive, the modest specificity of conventional MRI modalities for cortical demyelination indicates that they are influenced by cortical changes other than demyelination. Improved acquisition and post-processing are needed to reliably measure cortical lesion load.
Keywords
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.