Abstract
Background and aim:
HD patients using dialysis catheters have been associated with chronic inflammatory state. In Egypt 6.6% of HD patients use catheters, of which short term catheters represent 59.6% and 40.4% with long-term catheters. In this study, we
Methods:
Sixty ESRD patients from hemodialysis units in Ain-Shams University hospitals (ASUH) at the time of catheter insertion we enrolled in our study. They were randomized into two groups:
Results:
At the end of the study, Inflammatory markers were significantly higher in group 2 (p-value: 0.045, 0.001, and 0.018 for WBCs, hsCRP and IL-6, respectively). Group 1 had better dialysis adequacy assessed by URR (p-value: 0.007 and 0.001, respectively). CRBSI were demonstrated in nine patients in group 2 (30%) in contrast to one patient only in group 1(3.3%) (p-value: 0.006) with pseudomonas being the most common isolated organism (27.7%).
Conclusion:
Use of (Taurolock-hep500™) for temporary hemodialysis catheters was associated with lower levels of inflammation markers and lower incidence of CRBSI and better catheter performance.