Abstract
Background:
The tunneling technique is currently widely used for placement of CVC. Recently, some clinicians have used this technique for peripherally inserted central catheters (PICC), or Midline catheters (MCs).
Objective:
To describe a safe antegrade tunneling technique for PICCs and MCs insertion with a blunt tunneler.
Methods:
This retrospective monocentric survey collected ASST Lodi hospital data from January 1st to December 31st, 2019. The indication for PICCs and MCs tunneled implant was to respect the correct vein/catheter ratio or special clinical situation (children, burns, wounds, and wider catheter 5/6 fr). Contraindications included the operator’s low skills and severe risk of bleeding (INR > 3; Platelet count <50’000).
Results:
About 390 PICCs (327 4 fr and 63 5 fr) and 183 MCs were placed. One hundred and sixty-five PICCs (42%) and 110 MCs (60%) were tunneled. Five fr PICCs were more present among tunneled catheters (54/165 [32.7%] vs 9/225 [4%]
Conclusions:
The antegrade tunneling technique with blunt tunneler of PICCs and MCs is simple, rapid and is regarded as a safe maneuver. More in-depth and future prospective studies are needed to evaluate the impact of tunneling on early and late complications.
Get full access to this article