Arterial line catheterization in the critically ill patient is often an arduous task. Here we identify risk factors in the critical care patient that may predict a more difficult arterial catheter insertion. We also describe our ultrasound technique and review of the literature with regard to location of access, complications, and the use of ultrasound guidance.
MigniniM.A., PiacentiniE., DubinA.. Peripheral arterial blood pressure monitoring adequately tracks central arterial blood pressure in critically ill patients: an observational study.Crit Care2006; 10: R43: 1–5.
2.
FrezzaE.E., MezghebeH.. Indications and complications of arterial catheter use in surgical or medical intensive care units:: analysis of 4932 patients.Am Surg1998; 64: 127–31.
3.
MartinC., SauxP., PapazianL., GouinF.. Long-term Arterial Cannulation in ICU Patients Using the Radial Artery or Dorsalis Pedis Artery.Chest2001; 119: 901–6.
4.
TegtmeyerK., BradyG., LaiS., HodoR., BranerD.. Placement of an Arterial Line.N Engl J Med2006; 345: e13–14.
5.
ShiverS., BlaivasM., LyonM.. A prospective comparison of ultrasound-guided and blindly placed radial arterial catheters.Acad Emerg Med2006; 13: 1275–9.
6.
RonaldA., PatelA., DunningJ.. Is the Allen's test adequate to safely confirm that a radial artery may be harvested for coronary arterial bypass grafting?Interact Cardiovasc Thorac Surg2005; 4: 332–40.
7.
CoulterT.D., WiedemannH.D.. Complications of hemodynamic monitoring.Clin Chest Med1999; 2: 249–67.
8.
OharaU., NakayamaS., FurukawaH., SatohY., SuzukiH., YanaiH.. Use of a wired-guided canniula for radial arterial cannulation.J Anesth2007; 21: 83–5.
9.
BeardsS.C., DoedensL., JacksonA., LipmanA.. A comparison of arterial lines and insertion techniques in critically ill patients.Anesthesia1994; 49: 968–73.
10.
GuilloryaR.K., GunterbO.L.. Ultrasound in the surgical intensive care unit.Cur Opin Crit Care2008; 14: 415–22.
11.
WilsonS.R., GrunsteinI., HirvelaE.R., PriceD.D.. Ultrasound-guided radial artery catheterization and the modified Allen's test.J Emerg Med.2008; 1: 1–5.
12.
LevinP.D., SheininO., GozalY.. Use of ultrasound guidance in the insertion of radial artery catheters.Crit Care Med2003; 31: 481–4.
13.
BarakatH., TruwitJ.D.. Radial artery “mycotic” pseudoaneurysm occurring after arterial line placement: case report and review of the literature.Clin Pulm Med2003; 10: 289–94.
14.
RikerA.I., GamelliR.L.. Vascular complications after femoral artery catheterization in burn patients.J Trauma1996; 41: 904–6.
15.
ScheerB., PerelA., PfeifferU.J.. Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine.Crit Care2002; 3: 199–204.
16.
SandhuN.S.. The use of ultrasound for axillary artery catheterization through pectoral muscles: a new anterior approach.Anesth Analg2004; 99: 562–5.
17.
SongH., KangY., WeiX., WeiW., LiuJ.. A new ultrasound-guided arterial cannulation method in sever trauma improve success rate.Anesthesiology2007; 107: A1708.