Abstract
Introduction:
As the volume of technology-assisted total hip arthroplasty (THA) increases, there is a need to characterise the outcomes of robotic-assisted (RA) and computer-navigated (CN) THA. The goal of this study was to assess outcomes and opioid consumption following CN-THA and RA-THA compared to conventionally-instrumented (CON) THA.
Methods:
The Premier Database was queried for all patients who underwent primary, elective THA from 2015-2020. Patients were divided into 3 groups: CN, RA, or CON-THA. Yearly usage trends were assessed. Univariate and multivariate analyses were performed to assess the 90-day risk of postoperative complications. Opioid consumption was reported in morphine milligram equivalents (MME) for postoperative days (POD) 0 and 1.
Results:
Overall, 474,707 elective THAs were identified (95.7% CON, 2.1% CN, 2.2% RA. After accounting for confounders, CN-THA patients were at decreased risk for periprosthetic joint infection (PJI) (aOR: 0.55,
Discussion:
CN-THA was associated with reduced rates of PJI and dislocation, but increased rates of blood transfusion while RA-THA was associated with decreased rates of dislocation, but increased rates of blood transfusion, prosthesis complications, and periprosthetic fracture compared to CON-THA. Technology-assisted THA was associated with lower postoperative opioid consumption.
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.