With a view to selecting the most suitable suture material for scleral wound management we made histological and tensiometric scar examinations after 7, 21 and 45 days on rabbits’ eyes. Suture materials were also observed under the scanning electron microscope at the same intervals. Three suture materials (virgin silk 8.0, polyglycolic acid 7.0 and Nylon 8.0) were tested. Polyglycolic acid proved the most suitable suture material for this purpose.
JayJ.L.Perforating injuries of cornea and sclera.Trans Ophthalmol Soc UK1982; 102: 218–20.
3.
DavisonP.F., GalbavyE.J.Connective tissue remodelling in corneal and scleral wounds.Invest Ophthalmol Vis Sci1986; 27: 1478–84.
4.
ZagoskiZ.Experimental studies on the healing of scleral injuries during surgery of intraocular foreign bodies.Klin Oczna1987; 89: 1–3.
5.
MorseP.H.Repair of scleral lacerations with 8.0 white virgin silk sutures.Am J Ophthalmol1969; 67: 854–6.
6.
ChaterijeeS.Comparative trial of Dexon (polyglycolic acid) collagen and silk sutures in ophthalmic surgery.Br J Ophthalmol1975; 59: 736–40.
7.
SalthouseT.N., MatlagaB., WykoffM.N.Comparative tissue response to six suture materials in rabbit cornea, sclera and ocular muscle.Am J Ophthalmol1977; 84: 224–33.
8.
Mc ClellanK.A., KnoilA., BillsdonF.A.Nonabsorbable suture material in corneoscleral sections - a comparison of novafil and nylon.Ophthalmic Surg1989; 20: 480–5.
9.
Mc ClellanK.A., BillsonF.A.Long term comparison of nofavil and nylon in corneoscleral sections.Ophthalmic Surg1991; 22: 74–7.
10.
GallowayN.R.Which suture material? (Editorial, comment).Eye1991; 5: VII.