Abstract
Purpose
To evaluate and compare intraocular lens (IOL) tilt between uneventful phacoemulsification with in-the-bag IOL implantation and sutured scleral fixation (SSF) of the lens bag with a capsular tension segment (type 6 D / Morcher) using a Sheimpflug camera.
Setting
Clinical Practice, Hospital. Barcelona and A Coruña, Spain.
Design
Retrospective, comparative multicenter study.
Methods
IOL tilt was compared between patients who underwent sutured scleral fixation with a capsular tension segment in a single eye (SSF group, n = 15) with patients who underwent uneventful IOL implantation (control group, n = 12) that were matched by biometric measurements. Post-operative refractive accuracy of biometric formulas by means of mean absolute error (MAE) was also reported. All patients underwent a general ophthalmic evaluation, anterior segment photography, and postoperative optical biometry (Zeiss IOLMaster® 500). In addition, IOL tilt was measured with a Scheimpflug camera (Pentacam R, Oculus Optikgerate Gmbh).
Results
Mean vertical tilt was similar in both groups (2.20+/-2.47° SSF vs 1.97 +/- 1.79° control; p = 0.836) but mean horizontal tilt tended to higher values in the SSF series (2.09 +/- 2.74° vs 0.94 +/- 1.17°; p = 0.139). Considering post-operative refractive error in diopters by MAE calculations, there was an underestimation of IOL power in the SSF group which was only statistically significant for Barrett Universal II (1.07 vs 0.32; p = 0.028) and Hill-RBF (0.95 vs 0.26; p = 0.024) formulas, but not for SRK/T (0.99 vs 0.42; p = 0.285) and Kane (0.96 vs 0.33; p = 0.083).
Conclusion
Sutured scleral fixation of capsular tension segments in the presence of zonular instability does not seem to induce clinically significant IOL tilt compared to uneventful cataract extraction cases.
Keywords
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.