Abstract
Purpose
To describe Reverse four-throw (RFT) technique for pupilloplasty.
Methods
The technique involves making a single pass through the anterior chamber that helps achieve a posteriorly directed suture knot. A single arm 9-0 polypropylene suture attached to long arm needle engages the iris defects with the tip of the needle piercing the iris tissue from the posterior surface and emerging from the anterior aspect. The suture end is passed from the loop with four throws taken consecutively in the same direction that create a self-sealing and self-retaining lock like single-pass four-throw technique but with the difference that the knot slides on the posterior surface of the iris tissue.
Results
The technique was performed in 9 eyes and the suture-loop easily slided along the posterior surface of iris tissue. The iris defect was well approximated in all the cases and the suture knot or suture tail was not visible in the anterior chamber. Anterior segment optical coherence tomography depicted smooth iris configuration with no suture extrusion in the anterior chamber.
Conclusions
The RFT technique provides an effective measure to seal the iris defect with the absence of knot in AC.
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.