Abstract
Introduction
We described a case of initial unsuccessful outcome of failed macular hole treated with amniotic membrane, that resolved after amniotic membrane exchange and silicone oil injection.
Case Description
a woman affected by a high myopic macular hole that had failed to close after multiple surgeries, had been treated using an amniotic membrane graft and 20% sulfur hexafluoride but, after the gas reabsorption, the macular hole was still open, and the amniotic
membrane. A second surgery with a second amniotic membrane patch and silicone oil was carried out. Two weeks after the procedure the macular hole closed, and the final visual acuity improved from 20/400 to 20/100.
Conclusions
In this case, a second surgery, using a new amniotic membrane graft and a longer-lasting endotamponade, closed the hole and improved the visual acuity.
Keywords
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.