Abstract
Purpose:
Late hypotony is an undesirable and challenging complication of glaucoma surgery. We describe our use of the Ologen Collagen Matrix to treat late hypotony developing after trabeculectomy.
Study design:
A retrospective study performed at three eye surgery centers in Brazil.
Participants:
Eighteen patients who underwent 19 eye surgeries.
Intervention:
Subconjunctival Ologen was implanted at the trabeculectomy sites to treat over-filtering or leaking blebs in patients experiencing late hypotony after trabeculectomy (obtained 6 months after glaucoma surgery). The primary outcome was the intraocular pressure (IOP); we gathered preoperative data records from 19 Ologen treated eyes and days 1, 7, 30, 60, and 180 postoperatively. The secondary outcomes included visual acuity and macular thickness measured via optical coherence tomography; we compared preoperative data to subsequent ones up to sixth-month-evolution.
Results:
Over the 6-month period, the IOP rose from 2.89 ± 1.59 mmHg preoperatively to 8.21 ± 3.46 mmHg (p = 0.0001). Visual acuity improved from 0.33 ± 0.29 to 0.21 ± 0.31 LogMar (p = 0.0013). Macular thickness fell from 325.62 ± 58.7 to 283.08 ± 47.35 µm (p = 0.0097). We encountered two complications: one related to suture dehiscence following an ocular trauma and one instance of transitory choroidal detachment.
Conclusion:
Subconjunctival Ologen implants preserved bleb function and successfully treated post-trabeculectomy hypotony as revealed by data collected at the 6-month follow-up. Longer follow-up is necessary to confirm long-term efficacy and safety. There are no financial conflicts of interest to disclose.
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.