Abstract
Management of mis-dissected lenticule during Small-incision lenticule extraction (SMILE) is technically challenging and might be experienced more by novice surgeons especially in eyes with low refractive errors and thin lenticules. Presently, we describe a rescue method of inverse centripetal dissection (ICD) to manage mis-dissected lenticules. In this technique, after inadvertent dissection of posterior plane prior to anterior plane, the double-ended SMILE dissector is rotated along its shaft axis clockwise from the left upper margin of the mis-dissected lenticule to form an inversely folded lenticule which is then subsequently dissected centripetally till midline. This is then extracted by performing lenticulorrhexis with a pair of microforceps. We performed this technique in 10 eyes of 10 patients and the lenticule extraction was accomplished successfully in all eyes. At six months follow-up, the uncorrected visual acuity was 20/20 with a clear interface in all eyes. The ICD approach might serve as a useful rescue technique for managing mis-dissected lenticules.
Keywords
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.