Fluctuating anterior chamber depth and reverse pupillary block are the most common problems encountered during phacoemulsification following pars plana vitrectomy in cases of cataracts. The sudden deepening of the anterior chamber makes the surgical procedure more cumbersome and increases the risk of intraoperative complications. To solve this problem, we describe a method of balancing the pressure of the anterior and posterior chamber by using a syringe with a flushing needle to inject balanced salt solution into the posterior chamber via the gap between the iris and the anterior capsule of the lens. This technique is especially suitable for complicated cataracts following previous pars plana vitrectomy and high myopia-complicated cataracts. This technique yielded promising results in reducing the difficulties that occur during surgical procedures, reduced the risk of intraoperative complications and simplified the intraocular lens implantation.
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.