Abstract
The aim of this article is to report the results of an innovative technique for a scleral fixation of a posterior chamber intraocular lens using our new modified technique. We retrospectively reviewed the medical records of 15 eyes of 15 patients who underwent sutureless intrascleral intraocular lens fixation using our modified technique. We used a 23-gauge knife to perform sclerotomy and create two parallel scleral pockets for the haptics. The mean follow-up period was 3 years (3 ± 1). No complications were detected during the follow-up period. The creation of two parallel scleral pockets, parallel to the limbus, greatly simplifies the introduction of intraocular lens haptics.
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.