Various samples of cellulose insulation were evaluated for flash-fire propensity, using the test method developed at the University of San Francisco. The samples included untreated cellulose insulation and insulation treated with various levels of 5-mol borax, boric acid, and mix tures of boric acid and 5-mol borax. Boric acid appeared to reduce flash- fire propensity most effectively, and a mixture of boric acid and 5-mol borax was less effective than either material used separately.
Get full access to this article
View all access options for this article.
References
1.
J.E. Brown and J.J. Comeford, "A Technique for the Measurement of Flash-Fire Potential of Polymeric Materials," NBSIR 75-757, National Bureau of Standards, Washington, D.C. (December 1975).
2.
B.W. Kuvshinoff , R.M. Fristrom, G.L. Ordway, and R.L. Tuve, "Fire Sciences Dictionary," John Wiley and Sons, New York (1977 ).
3.
C.J. Hilado and H.J. Cumming, "A Simple Laboratory Method for Determining Flash-Fire Propensity of Materials," Journal of Fire and Flammability , Vol. 8, No. 3, 332—348, (July 1977).
4.
C.J. Hilado and H.J. Cumming, "Flash Fire Propensity of Materials ," Journal of Fire and Flammability, Vol. 8, No. 4, 443-457, (October 1977).