BarbeitoM.S. & KruseR.H.1997. A history of the American Biological Safety Association
Part I: The first ten biological safety conferences 1955–1965. J. Am. Biol. Saf. Assoc., 2(3):7–19.
2.
KruseR.H. & BarbeitoM.S.1997. A history of the American Biological Safety Association
Part II: Safety conferences 1966–1977. J. Am. Biol. Saf.
Assoc., 2(4):10–25.
3.
National Sanitation Foundation. 1976. Class II (laminar flow) biohazard
cabinetry. National Sanitation Foundation standard no.
49. National Sanitation Foundation, Ann Arbor, MI.
4.
WedumA.G.1953. Bacteriological safety. Am. J.
Public Health, 43:1428–1437.
5.
TABLE 1 Selected Publications by
Participants at the Ten Biological Safety Conferences
1978–1987.
6.
AllnerK.1980. Laboratory and equipment design for containment of
biohazards, p. 467–485. In ClooneyC.L. & HumphreyA. (ed.), Comprehensive biotechnology. Pergamon
Press, Oxford.
7.
BarbeitoM.S.1979. Special design features for maintenance requirements of a biomedical facility, p. 177–193. In FoxD.G. (ed.), Design of biomedical research facilities;. proceedings of a cancer research symposium 1979 October 18–19, Frederick Cancer Research Center, Frederick, MD. NIH publ. no. 81–2305. National Institutes of Health, Bethesda,
MD.
8.
British Standards Institution. 1979. Specifications for microbiological safety
cabinets, Brit. Std. 5726. British
Standards Institution, London.
9.
Centers for Disease Control. 1987. Recommendations for prevention of HIV transmission in
health care settings. Morbid. Mortal. Weekly Rep. 36(Suppl.
S-6):1–48.
10.
ConnerT.H., TheissJ.C., AndersonR.W., PuckettW.H.Jr. & MatneyT.S.1986. Re-evaluation of urine mutagenicity of pharmacy
personnel exposed to antineoplastics. Am. J. Hosp.
Pharm., 43:136–1239.
11.
FaveroM.S., PetersenN.J. & BondW.W.1986. Transmission and control of laboratory-acquired
infection, p. 49–58. In MillerB.M., GroschelD.H.M., RichardsonJ.H., VesleyD., SongerJ.R. & HousewrightR.D. & BarkleyW.E. (ed.), Laboratory safety; principles and practices. American Society for Microbiology, Washington, DC.
12.
Federal Register. 1980. Interstate shipment of etiologic
agents. Fed. Regist., 45:48626–48627.
13.
GibbsC.J.Jr. & GajdusekD.C.1978. Atypical viruses as the cause of sporadic epidemic, and
familial chronic disease in man; slow viruses and human diseases, p.
161–198. In Perspectives in virology, Vol.
10. Raven Press, NY.
14.
Harvard University School of Public
Health. 1987. Testing class II laminar airflow cabinets
(course). Harvard University School of Public
Health, Boston, MA.
15.
International Agency for Research on
Cancer, World Health Organization. 1981. Evaluation
of the carcinogenic risk of chemicals to humans: some antineoplastic and
immunosuppressive agents. IARC Monogr., 26:37–384.
16.
Johns Hopkins University School of Hygiene
and Public Health. 1980. Control of biohazards in research
laboratories (course). Sponsored by Division of Safety,
National Cancer Institute, Johns Hopkins University School of Hygiene and Public
Health, Baltimore, MD.
17.
Joint Commission on Accreditation of
Hospitals. 1984. Accreditation manual for
hospitals, 1985. Joint Commission on Accreditation of
Hospitals. Chicago.
18.
KentP.T. & KubicaG.P.1985. Public health mycobacteriology: a guide for the level III
laboratory. U.S. Department of Health and Human Services
publ. no. (CDC) 85–3439. U.S. Government Printing
Office, Washington, DC.
19.
KirchheimerW.F.1972. Animal models for research in leprosy. J. Med. Assoc. Thailand, 55:605–609.
LauerJ.L., Van DrunenN.A., WashburnJ.W., BalfourH.H.Jr.1979. Transmission of hepatitis B in the clinical laboratory
areas. J. Infect. Dis., 140:513–516.
22.
MacherJ.M. & FirstM.W.1984. Effects of airflow rates and operator activity on
containment of bacterial aerosols in a class II safety cabinet. Appl. Environ. Microbiol., 48:481–485.
23.
MillerB.M., GroschelD.H.M., RichardsonJ.H., VesleyD., SongerJ.R., HousewrightR.D. & BarkleyW.E.1986. Laboratory safety: principles and practices. American Society for Microbiology, Washington, DC.
24.
MillerC.D., SongerJ.R. & SullivanJ.F.1987. A twenty-five year review of laboratory-acquired human
infection at the National Animal Disease Center, Am. Ind. Hyg.
Assoc. J., 48:271–275.
25.
RakeB.W.1978. Influence of cross drafts on the performance of a
biological safety cabinet. Appl. Environ. Microbiol., 36:278–283.
26.
RakeB.W.1979. Microbiological evaluation of a biological safety
cabinet modified for bedding disposal. Lab. Anim. Sci., 29:625–632.
27.
RutalaW.A., StiegelM.M., SarubbiF.A.Jr.1982. Decontamination of laboratory microbiological waste by
steam sterilization. Appl. Environ. Microbiol., 43:1311–1316.
28.
ShopeR.E.1980. Arboviruses, p. 869–874. In LennetteE.H., BalowsA., HauslerW.J.Jr. & TruantJ.P. (ed), Manual of clinical microbiology, 3rd ed. American Society for Microbiology, Washington, DC.
29.
StuartD.G., GreenierT.J., RumeryR.A. & EaglesonJ.M.1982. Survey, performance and use of biological safety
cabinets. Am. Ind. Hyg. Assoc., 43:265–270.
30.
StybloK.1984. Epidemiology of tuberculosis. Infektionskrankheiten und ihre Erreger. 4/VI: 77–161. VEB Gustav Fischer Verlag
Jena.
31.
U.S. Department of Health and Human
Services. 1984. Biosafety in microbiological and
biomedical laboratories. HHS publ. no. (CDC) 84–8395. U.S.
Government Printing Office, Washington,
DC.
32.
VesleyD. & HartmanH.H.1988. Laboratory-acquired infections and injuries in clinical
laboratories: a 1986 survey. Am. J. Public Health, 78:245–256.