Abstract
Introduction
Left ventricular chamber size and functional assessment by transesophageal echocardiography can be difficult if visualization is poor in the mid-esophageal views. However, the accuracy of using the Simpson’s method in the transgastric 2-chamber (TG2C) as an alternative approach has not been assessed.
Methods
The Simpson’s method was performed by 2 independent reviewers using midesophageal 2-chamber (ME2C) and TG2C views. Echocardiographic images were retrieved retrospectively for 49 adult cardiac surgical patients.
Results
Two-way random effects intraclass correlation coefficients demonstrated no significant interobserver variability. Linear mixed effects models showed no significant differences in ME2C and TG2C measurements with regard to EDV (P=.4407), ESV (P=.5113), or EF (P=.0610).
Compared to the ME2C view, the TG2C view had better image quality of the LV walls (image quality score median [interquartile range]: 2.00 [.00] vs 1.00 [1.00]; P<.0001), but worse image quality of the mitral annulus (1.00 [1.00] vs 2.00 [.00]; P<.0001) and LV apex (.00 [1.00] vs 2.00 [1.00]; P<.0001).
Conclusions
This study suggests the Simpson’s method can be applied to the TG2C view as an alternative to the standard midesophageal method to estimate chamber volumes and EF.
Keywords
Get full access to this article
View all access options for this article.