BossertTGummertJFBittnerHB. Swan-Ganz catheter-induced severe complications in cardiac surgery: right ventricular perforation, knotting, and rupture of a pulmonary artery. J Card Surg. 2006;21:292-295.
2.
FengWCSinghAKDrewT.Swan-Ganz catheter-induced massive hemoptysis and pulmonary artery false aneurysm. Ann Thorac Surg. 1990;50:644-646.
3.
AliMJOmranASRakowskiHRWilliamWG.Pulmonary valve injury: Swan-Ganz or surgery. Can J Cardiol. 2001;17:467-470.
4.
AbreuARCamposMAKriegerBP.Pulmonary artery rupture induced by a pulmonary artery catheter: a case report and review of the literature. J Intensive Care Med. 2004;19:291-296.
5.
AggarwalNKupferYYoonTSTesslerS.Pulmonary artery catheter coiled in the main pulmonary artery trunk. BMJ Case Rep. 2013;2013. doi:10.1136/bcr-2013-200049.
6.
ArnaoutSDiabKAl-KutoubiAJamaleddineG.Rupture of the chordae of the tricuspid valve after knotting of the pulmonary artery catheter. Chest. 2001;120:1742-1744.
7.
SantiniFMessinaAMazzuccoA.Swan-Ganz bipolar pacing catheter entrapment in the tricuspid valve apparatus. Eur J Cardiothorac Surg. 2006;29:842
8.
KalińczukLChmielakZDębskiA. Percutaneous retrieval of centrally embolized fragments of central venous access devices or knotted Swan-Ganz catheters. Clinical report of 14 retrievals with detailed angiographic analysis and review of procedural aspects. Adv Interv Cardiol. 2016;12:140-155.
9.
EvansDCDoraiswamyVAProsciakMP. Complications associated with pulmonary artery catheters: a comprehensive clinical review. Scand J Surg. 2009;98:199-208.
10.
NellaiyappanMOmarHRJustizRSprenkerCCamporesiEMMangarD.Pulmonary artery pseudoaneurysm after Swan-Ganz catheterization: a case presentation and review of literature. Eur Heart J Acute Cardiovasc Care. 2014;3:281-288.
11.
RudzińskiPNHenzelJDzielińskaZ. Pulmonary artery rupture as a complication of Swan-Ganz catheter application. Diagnosis and endovascular treatment: a single centre’s experience. Postepy Kardiol Interwencyjnej. 2016;12:135-139.
12.
DerenMMBarashPGHammondGLSaiehT.Perforation of the pulmonary artery requiring pneumonectomy after the use of a flow-directed (Swan-Ganz) catheter. Thorax. 1979;34:550-553.
GottwallesYWunschel-JosephMEHanssenM.Coil embolization treatment in pulmonary artery branch rupture during Swan-Ganz catheterization. Cardiovasc Intervent Radiol. 2000;23:477-479.
15.
YouCKWhatleyGS.Catheter-induced pulmonary artery pseudoaneurysm: a case of complete resolution without intervention. Can J Surg. 1994;37:420-424.
16.
RouquierJArrivéLMasiniJPMonnier-CholleyLLewinMTubianaJM.Spontaneous resolution of asymptomatic false aneurysm of the pulmonary artery induced by Swan-Ganz catheter [in French]. J Radiol. 2001;82(12pt 1):1732-1734.
17.
BianchiniRMelinaGBenedettoU. Extracorporeal membrane oxygenation for Swan-Ganz induced intraoperative hemorrhage. Ann Thorac Surg. 2007;83:2213-2214.