Abstract
Introduction
Maintaining safe working environments for health care personnel, especially for those who regularly handle hazardous drugs (HDs), is of utmost importance. Studies have shown that when closed system transfer devices (CSTDs) are used with standard open barrel syringes, cyclophosphamide (CP), a commonly used HD, is transferred to the syringe plunger during compounding or administration processes. This contamination can then be transferred to the work environment, endangering workers.
Purpose
The purpose of this study was to quantify HD contamination of the inner surface of standard open barrel syringes and to compare contamination levels between three commonly used HDs: 5-fluorouracil (5-FU), CP, and ifosfamide (IF).
Methods
Each HD was transferred from a vial to an intravenous (IV) bag using a standard open barrel syringe and Becton, Dickinson and Company (BD) PhaSealTM CSTD connectors. Samples were taken from the inner surface of each of the syringe barrels to measure the amount of HD contamination. Each drug was tested 15 times and compared to a positive control.
Results
Significant amounts of each drug were transferred to the inner surfaces of the syringes. The average amounts of each drug measured were: 5-FU, 1327.7 ng (standard deviation [SD] = 873.6 ng); CP, 1074.8 ng (SD = 481.6 ng); and IF, 1700.0 ng (SD = 1098.1 ng). There was no statistically significant difference between the three drugs (p = 0.14).
Conclusion
This study underscores the presence of HD contamination on standard open barrel syringe inner surfaces after transfer of drug from vial to syringe to IV bag. Such contamination could be spread in the working environment and expose health care workers to harm.
Keywords