Abstract
Background:
Although double-row suture-anchored (DRSA) techniques for Achilles insertional tendinosis has proven successful, a reoccurring failure mode not yet addressed is suture tearing through the tendon. This study aims to address suture tearing by incorporating a rip-stop element. Authors hypothesized that the Rip-Stop group would demonstrate increased strength compared with more traditional techniques.
Methods:
12 paired cadaveric feet were used in this study (n = 24). One sample from each pair was assigned to receive the standard double-row (SDR) Achilles repair with 4.75-mm knotless anchors (n = 12). The control’s matched sides were divided between 2 DRSA bridge groups: modified double-row (MDR) bridge with 3.9-mm anchors or rip-stop double-row (RS-DR) bridge repair with soft proximal anchors and 3.9-mm anchored distal row. In neutral position, specimens underwent 1000 cycles (20-100 N) followed by load to failure. Displacements, stiffness, ultimate load, and failure mode were recorded.
Results:
RS-DR had the lowest initial displacement values followed by SDR and MDR (1.3 ± 0.4, 2.7 ± 1.4, and 3.2 ± 1.3 mm, respectively). Significance was detected when comparing initial displacement of RS-DR to MDR (P = .038). Cyclic displacement was lowest for RS-DR, followed by MDR and SDR (1.6 ± 0.9, 2.2 ± 1.1, and 4.5 ± 3.2 mm, respectively). Cyclic stiffness was similar for RS-DR and MDR (89.1 ± 24.6 and 81.9 ± 5.6 N/mm, respectively). RS-DR ultimate load (1116.8 ± 405.7 N) was statistically greater than SDR (465.6 ± 352.7, P = .003).
Conclusion:
RS-DR–repaired specimens demonstrated a decrease in displacement values and increased ultimate load and stiffness when compared to other groups. Results of this cadaveric model suggest that the addition of a rip-stop to DRSA Achilles repair is more impactful than anchor size. Limitations include that this was a time-zero biomechanical study, which cannot simulate the performance of the repairs during postoperative healing and recovery.
Clinical Relevance:
A rip-stop technique for Achilles repair effectively improves dynamic mechanical characteristics and may mitigate suture tearing through tendon in a patient cohort.
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.