Abstract
The in vitro heparin sensitivity of 6 different commercial activated partial thromboplastin time (APTT) reagents was investigated based on artificial plasma samples prepared by addition of sodium heparin at different activities (0—1.5 IU/ml) to pooled normal canine plasma. Statistical analysis using 2-way analysis of variance was based on APTT ratios (APTT/mean APTT control). Significant differences between the APTT ratios of different APTT reagents (P < 0.00001) were found, which also depended on heparin activity (interaction between the factors; P < 0.00001). For example, mean APTT ratio at 0.7 IU/ml heparin varied between 1.2 and 2.5. The results of this study indicate that recommendations for the control of heparin therapy in dogs by APTT ratio should be reagent specific.