Abstract
Objective
To evaluate the ability of the Modified Acute Physiology and Chronic Health Evaluation (M-APACHE II) scoring system for the prediction of mortality in patients admitted to a tertiary emergency department in Iran.
Methods
During the study period, all patients aged >12 years who had been admitted to the emergency department of a tertiary hospital in Tehran, Iran were enrolled in the study. Traumatic and poisoned patients and those who died immediately after arriving at the emergency room were excluded. Using the M-APACHE II, risk of mortality was calculated for each patient. Finally, expected and observed mortalities were compared and the accuracy of M-APACHE II for prediction of mortality was determined using receiver operating characteristics (ROC) analysis.
Results
During the study period, 389 cases including 236 males (60.7%) were enrolled into the study. The mean age of the patients was 60.6±19.4 years (range 14 to 98 years). 117 patients died (30%) while the M-APACHE II predicted 129 deaths. The greatest discrepancy between observed and expected deaths occurred at M-APACHE II scores ≥21. The constructed area under the ROC curve basng on predicted and observed death was 0.938 (95% confidence interval 0.915-0.961).
Conclusion
M-APACHE II is an accurate scoring system for predicting mortality in patients admitted to the emergency department. However, further studies are needed to confirm our findings.