Abstract
Background:
Anticoagulation monitoring practices vary during extracorporeal membrane oxygenation (ECMO). The Extracorporeal Life Support Organization describes that a multimodal approach is needed to overcome assay limitations and minimize complications.
Objective:
Compare activated clotting time (ACT) versus multimodal approach (activated partial thromboplastin time (aPTT)/anti-factor Xa) for unfractionated heparin (UFH) monitoring in adult ECMO patients.
Methods:
We conducted a single-center retrospective pre- (ACT) versus post-implementation (multimodal approach) study. The incidence of major bleeding and thrombosis, blood product and antithrombin III (ATIII) administration, and UFH infusion rates were compared.
Results:
Incidence of major bleeding (69.2% versus 62.2%, p = 0.345) and thrombosis (23% versus 14.9%, p = 0.369) was similar between groups. Median number of ATIII doses was reduced in the multimodal group (1.0 [IQR 0.0-2.0] versus 0.0 [0.0 -1.0], p = 0.007). The median UFH infusion rate was higher in the ACT group, but not significant (16.9 [IQR 9.6-22.4] versus 13 [IQR 9.6-15.4] units/kg/hr, p = 0.063). Fewer UFH infusion rate changes occurred prior to steady state in the multimodal group (0.9 [IQR 0.3 -1.7] versus 0.1 [IQR 0.0-0.2], p < 0.001).
Conclusion:
The incidence of major bleeding and thrombosis was similar between groups. Our multimodal monitoring protocol standardized UFH infusion administration and reduced ATIII administration.
Keywords
Get full access to this article
View all access options for this article.