ErsoyF.F., TwardowskiZ.J., SatalowichR.J., KetchersidT.A retrospective analysis of catheter position and function in 91 CAPD patients.Perit Dial Int1994; 14: 409–10.
2.
AkyolA.M., PorteousC., BrownM.W.A comparison of two types of catheters for continuous ambulatory peritoneal dialysis (CAPD).Perit Dial Int1990; 10: 63–6.
3.
Diaz-BuxoJ.A.Peritoneal dialysis catheter malfunction due to compartmentalization.Perit Dial Int1997; 17: 209–10.
4.
BlockR.A., TaylorB., FrederickG.Intraperitoneal infusion of streptokinase in the treatment of recurrent peritonitis.Perit Dial Bull1983; 3: 162.
5.
BeneventD., PeyronnetP., BrignonP., Leroux-RobertC.Urokinase infusion for obstructed catheters and peritonitis.Perit Dial Bull1985; 5: 77.
6.
WilliamsA., BoletisI., JohnsonB.F., RafteryA.T., CohenC.I., MoorheadP.J.Tenckhoff catheter replacement or intraperitoneal urokinase: A randomized trial in the management of recurrent continuous ambulatory peritoneal dialysis peritonitis.Perit Dial Bull1989; 9: 65–7.
7.
HashimotoY., YanoS., NakanishiY., SuzukiS., TsutsumiM.A simple method for opening an obstructed peritoneal catheter using an infusion accelerator. In: KhannaR., ed. Advances in peritoneal dialysis.Toronto: Peritoneal Dialysis Publications, 1996; 12: 227–30.
8.
MossJ.S., MindaS.A., NewmanG.E., DunnickN.R., VernonW.B., SchwabS.J.Malpositioned peritoneal dialysis catheters: A critical reappraisal of correction by wire manipulation.Am J Kidney Dis1990; 15: 305–8.
SimonsM., GayleneP., VorosM., VanderburghL.C., RaoP., OreopoulosD.G.Fluoroscopically guided manipulation of malfunctioning peritoneal dialysis catheters.1998 (Submitted for publication to the Journal of Vascular and Interventional Radiology).
15.
GadallahM.F., ArumugamR., MolesK., AroraN.The role of Fogarty catheter manipulation in the management of migrated, non-functional peritoneal dialysis Tenckhoff catheters (Abstract).J Am Soc Nephrol1997; 8: 179A.
16.
BrandtC.P., RicanatiE.S.Use of laparoscopy in the management of malfunctioning peritoneal dialysis catheters. In: KhannaR., ed. Advances in peritoneal dialysis.Toronto: Peritoneal Dialysis Publications, 1996; 12: 223–6.
17.
GarciaM.A.V., UreñaM.A.G., CarneroF., RuizE.F., RodriguezC.R., Perez De LastraP.A.Omental entrapping of peritoneal dialysis catheter solved by a laparoscopic approach.Perit Dial Int1997; 17: 194–5.
CrabtreeJ.H., FishmanA.Laparoscopic epiplopexy of the greater omentum and epiploic appendices in the salvaging of dysfunctional peritoneal dialysis catheters.Surg Laparosc Endosc1996; 6: 176–80.
21.
NijhuisP.H., SmuldersJ.F., JakimowiczJ.J.Laparoscopic introduction of a continuous ambulatory peritoneal dialysis (CAPD) catheter by a two-puncture technique.Surg Endosc1996; 10: 676–9.
22.
WilsonJ.A.P., SwartzR.D.Peritoneoscopy in the management of catheter malfunction during continuous ambulatory peritoneal dialysis.Dig Dis Sci1985; 30: 465–72.
23.
SmithD.W., RankinR.A.Value of peritoneoscopy for non-functioning continuous ambulatory peritoneal dialysis catheters.Gastrointest Endosc1989; 35: 90–2.
24.
GibsonD.H., HealseyR.N., PriceJ.H., DohertyC.C., DouglasJ.F.Laparoscopic repositioning of blocked peritoneal dialysis catheters in patients on CAPD (Letter).Clin Nephrol1990; 33: 208.
25.
ChaoS., TsaiT.Laparoscopic rescue of dysfunctional Tenckhoff catheters in continuous ambulatory peritoneal dialysis patients (Letter).Nephron1993; 65: 157–8.
PonceS.P., PierratosA., IzattS., MathewsR., KhannaR., ZellermanG.Comparison of the survival and complications of three permanent peritoneal dialysis catheters.Perit Dial Bull1982; 2: 82–6.
TwardowskiZ.J., NolphK.D., KhannaR., ProwantB.F., RyanL.P., NicholsW.K.The need for a “Swan neck” permanently bent, arcuate peritoneal dialysis catheter.Perit Dial Bull1985; 5: 219–25.
31.
FlaniganM.J., NgheimD.D., SchulakJ.A., UllrichG.E., FreemanR.M.The use and complications of three peritoneal catheter designs.ASAIO Trans1987; 33: 33–8.
32.
AllonM., SoucieJ.M., MaconE.J.Complications with permanent peritoneal dialysis catheters: Experience with 154 permanently placed catheters.Nephron1988; 48: 8–11.