Van BronswijkH., VerbrughH.A., BosH.J.Cytotoxic effects of commercial continuous ambulatory peritoneal dialysis (CAPD) fluids and of bacterial exoproducts on human mesothelial cells in vitro.Perit Dial Int1989; 9: 197–202.
2.
KristensenS.R., PedersenF.B.Cytotoxicity testing of two CAPD dialysis fluids in a model system of quiescent fibroblasts.Nephrol Dial Transplant1993; 8: 163–7.
3.
JörresA., GahlG.M.Effect of peritoneal dialysis fluids on leukocyte function.Perit Dial Int1994; 14(Suppl 3): S29–S32.
4.
IngB.L., GuptaD.K., NawabZ.M.Suppression of neutrophil superoxide production by conventional peritoneal dialysis solutions.Int J ArtifOrgans1988; 11: 351–4.
5.
LiberekT., TopleyN., JörresA.Peritoneal dialysis fluid inhibition of phagocyte function: Effects of osmolality and glucose concentration.J Am Soc Nephrol1993; 3: 1508–15.
6.
LiberekT., TopleyN., JörresA.Peritoneal dialysis fluid inhibition of polymorphonuclear leukocyte respiratory burst activation is related to the lowering of intracellular pH.Nephron1993; 65: 260–5.
7.
WieslanderA.P., NordinM.K., MartinsonE.Heat sterilized PD fluids impair growth and inflammatory responses of cultured cell lines and human leukocytes.Clin Nephrol1993; 39: 343–8.
8.
DuweA.K., VasS.I., WeatherheadJ.W.Effects of the composition of peritoneal dialysis fluid on chemiluminescence, phagocytosis and bactericidal activity in vitro.Infect Immun1981; 33: 130–5.
9.
DobbieJ.W., LloydJ.K., GallC.A.Categorization of ultrastructural changes in peritoneal mesothelium, stroma and blood vessels in uremia and CAPD patients. In: KhannaR., NolphK.D., ProwantB.F., TwardowskiZ.J., OreopoulosD.G. eds. Advances in peritoneal dialysis.Toronto: Peritoneal Dialysis Bulletin Inc., 1990; 6: 3–12.
10.
HeimburgerO., WaniewskiJ., WerynskiA.Peritoneal transport in CAPD patients with permanent loss of ultrafiltration capacity.Kidney Int1990; 38: 495–506.
11.
DobbieJ.W., PavlinaT., LloydJ.K.In vitro systems for testing effect of dialysate composition on mesothelium.Perit Dial Int1990; 10(Suppl 1): S51.
12.
BreborowiczA., KaronJ., KorybalskaK.Properties of mesothelial cells exposed to glucose or amino acid based dialysate effluents.Perit Dial Int1995; 15(Suppl 1): S76.
13.
GotloibL., WajsbrotV., ShostackA.Experimental approach to peritoneal morphology.PeritDialInt1994; 14(Suppl 3): S6–S11.
GallimoreB., GagnonR.F., StevensonM.M.Cytotoxicity of commercial peritoneal dialysis solutions towards peritoneal cells of chronically uremic mice.Nephron1986; 43: 283–9.
16.
JörresA., JörresD., TopleyN.Leukotriene release from peripheral and peritoneal leukocytes following exposure to peritoneal dialysis solutions.Nephrol Dial Transplant1991; 6: 495–501.
17.
TopleyN., MackenzieR., PetersenM.M.In vitro testing of a potentially biocompatible continuous ambulatory peritoneal dialysis fluid.Nephrol Dial Transplant1991; 6: 574–81.
18.
BreborowiczA., MartisL., OreopoulosD.G.Changes in biocompatibility of dialysis fluid during its dwell in the peritoneal cavity.Perit Dial Int1995; 15: 152–70.
19.
HaussingerD., LangF., GerokW.Regulation of cell function by the cellular hydration state.Am J Physiol1994; 267: E343–E355.
20.
WitowskiJ., TopleyN., JörresA.Effect of lactate-buffered peritoneal dialysis fluids on human peritoneal mesothelial cell interleukin-6 and prostaglandin synthesis.Kidney Int1994; 46: 282–93.
21.
BreborowiczA., RodelaH., MartisL., OreopoulosD.G.Intracellular glutathione in human peritoneal mesothelial cells exposedin vitro to dialysis fluid. (submitted)
22.
De FijterC.W.H., VerbrughH.A., PetersE.D.J.Invivo exposure to the currently available peritoneal dialysis fluids decreases the function of peritoneal macrophages in CAPD.Clin Nephrol1993; 39: 75–80.
23.
JörresA., TopleyN., SteenwegL.Inhibition of cytokine synthesis by peritoneal dialysate persists throughout the CAPD cycle.Am J Nephrol1992; 12: 80–5.
24.
Haag WeberM., HorlW.H.Impact of continuous ambulatory peritoneal dialysis solutions and clearance of macromolecules on polymorphonuclear neutrophils.Perit Dial Int1994; 14(Suppl 3): S33–S38.
25.
SteinhauerH.B., BruggerU., AtmanspacherR.Effect of CAPD dialysate on the release of eicosanoids and cytokines from human peritoneal macrophages. In: KhannaR., NolphK.D., ProwantB.F., TwardowskiZ.J., OreopoulosD.G. eds. Advances in peritoneal dialysis.Toronto: Peritoneal Dialysis Bulletin Inc., 1992: 47–52.
26.
DanielsI., LindsayM., PorterC.Effect of peritoneal dialysis effluent on superoxide anion production by polymorphonuclear neutrophils.Nephron1993; 64: 382–7.
27.
SelgasR., Lopez-RiasA., AlvaroF.Insulin influence (used as additive to dialysate) on the mitogenicinduced effect of the peritoneal effluent in CAPD patients. In: KhannaR., NolphK.D., ProwantB.F., TwardowskiZ.J., OreopoulosD.G. eds. Advances in peritoneal dialysis.Toronto: Peritoneal Dialysis Bulletin Inc., 1989: 161–4.
28.
BreborowiczA., OreopoulosD.G.Physiological approaches to increase biocompatibility of peritoneal dialysis.Perit Dial Int1995; 15(Suppl 7): S76–86.