Abstract
Objective
To make a comparison of serum levels of immunoglobulin G (lgG) subclasses in adult continuous ambulatory peritoneal dialysis (CAPD) patients with those in age-and sex-matched hemodialysis patients and healthy volunteers, and to analyze the contribution of removal of these proteins in peritoneal effluent to their plasma values.
Design
A cross-sectional study.
Setting
A renal unit of a university hospital.
Patients
Twenty-three CAPD patients, 21 hemodialysis patients, and 21 healthy volunteers. Peritoneal transport studies were done in 8 of the 23 CAPD patients.
Methods
IgG subclasses were measured in serum by nephelometry. For the peritoneal transport studies an ELISA method on ethylenediamine tetracetic acid plasma was used. The same method was used in seven-to ten-fold concentrated peritoneal dialysate.
Results
CAPD patients had lower IgG2 and IgG4 1evels than hemodialysis patients and healthy volunteers (p < 0.01). lgG2 values below 1.5 glL were present in 43% of the CAPD patients (p < 0.001 compared to healthy volunteers). Peritonitis incidence was not different between CAPD patients with low or normal IgG2 plasma levels. Peritoneal clearance of IgG3 was lower than that of the other subclasses. Evidence was obtained for a depressed synthesis of IgG2 and IgG4 in CAPD patients. The hypothesis that interleukin-2 may be involved in the low synthesis rate of IgG2 is discussed.
Conclusion
Low serum IgG2 and IgG4 1evels are present in stable, adult CAPD patients. These were not caused by increased peritonealloss, but by decreased synthesis.
Get full access to this article