Four co-operating centers evaluated the effects of a new dialysis solution containing 40 mEq/1 of lactate and 0.5 mEq/1 of magnesium on serum total CO2 and magnesium concentrations. The new solution yielded significant increases in serum CO2 and decreases in serum magnesium compared to the standard (35 mEq/1 of lactate and 1.5 mEq/1 of magnesium) solution.
Get full access to this article
View all access options for this article.
References
1.
NolphK.D., ParkerA.The composition of dialysis solutions for continuous ambulatory peritoneal dialysis. In: LegrainM., ed. Proceedings of an International Symposium.Paris, November 2–3,1979. Amsterdam, 1980: 341–346.
2.
NolphK.D., SorkinM.I., GloorH.J.Considerations for dialysis solution modifications. In: AtkinsR.C., ThomsonN.M., FarrellP.C., eds. Peritoneal dialysis.New York, 1981: 236–244.
3.
NolphK.D., SorkinM.I., ArfaniaD.Continuous ambulatory peritoneal dialysis - three years experience at a single center.Ann Intern Med1980; 92: 609–613.
4.
GillJ.L., HafsH.D.Analysis of repeated measurements of animals.J Animal Sci1971; 33: 331–336.
5.
CarterN.W.Regulation of acid-base balance in renal disease.The Kidney1973; 6: 1–5.
6.
ParkerA., NolphK.D.Magnesium and calcium net mass transfers during CAPD.Trans Am Soc Artif Intern Organs1980; 26: 194–196.