MistryC.D., GokalR., PeersE.A randomized multicenter clinical trial comparing isosmolar icodextrin with hyperosmolar glucose solutions in CAPD. MIDAS Study Group. Multicenter Investigation of Icodextrin in Ambulatory Peritoneal Dialysis.Kidney Int1994; 46: 496–503.
2.
JohnsonD.W., ArndtM., O'SheaA., WattR., HamiltonJ., VincentK.Icodextrin as salvage therapy in peritoneal dialysis patients with refractory fluid overload.BMC Nephrol2001; 2(1): 2.
3.
WolfsonM., PirainoB., HamburgerR.J., MortonA.R.A randomized controlled trial to evaluate the efficacy and safety of icodextrin in peritoneal dialysis.Am J Kidney Dis2002; 40: 1055–65.
4.
FinkelsteinF., HealyH., Abu-AlfaA., AhmadS., BrownF., GehrT.Superiority of icodextrin compared with 4.25% dextrose for peritoneal ultrafiltration.J Am Soc Nephrol2005; 16: 546–54.
5.
WoodrowG., StablesG., OldroydB., GibsonJ., TurneyJ.H., BrownjohnA.M.Comparison of icodextrin and glucose solutions for the daytime dwell in automated peritoneal dialysis.Nephrol Dial Transplant1999; 14: 1530–5.
6.
JelokaT.K., ErsoyF.F., YavuzM., SahuK.M., CamsariT., UtasC.What is the optimal dwell time for maximizing ultrafiltration with icodextrin exchange in automated peritoneal dialysis patients?Perit Dial Int2006; 26: 336–40.
7.
VenturoliD., JelokaT.K., ErsoyF.F., RippeB., OreopoulosD.G.The variability in ultrafiltration achieved with icodextrin, possibly explained.Perit Dial Int2009; 29: 415–21.
8.
JenkinsS.B., WilkieM.E.An exploratory study of a novel peritoneal combination dialysate (1.36% glucose/7.5% icodextrin), demonstrating improved ultrafiltration compared to either component studied alone.Perit Dial Int2003; 23: 475–80.
9.
FreidaP., GalachM., FilhoJ.C., WerynskiA., LindholmB.Combination of crystalloid (glucose) and colloid (icodextrin) osmotic agents markedly enhances peritoneal fluid and solute transport during the long PD dwell.Perit Dial Int2007; 27: 267–76.
10.
ParikovaA., SmitW., StruijkD.G., KredietR.T.Analysis of fluid transport pathways and their determinants in peritoneal dialysis patients with ultrafiltration failure.Kidney Int2006; 70: 1988–94. Epub 2006 Oct 11.
11.
WilliamsJ.D., CraigK.J., TopleyN., WilliamsG.T.Peritoneal dialysis: changes to the structure of the peritoneal membrane and potential for biocompatible solutions.Kidney Int Suppl2003; 84: 158–61.
12.
WangT., HeimburgerO., ChengH., WaniewskiJ., BergstromJ., LindholmB.Effect of increased dialysate fill volume on peritoneal fluid and solute transport.Kidney Int1997; 52: 1068–76.
13.
DurandP., ChanliauJ., GamberoniJ., HestinD., KesslerM.Intraperitoneal hydrostatic pressure and ultrafiltration volume in CAPD.Adv Perit Dial1993; 9: 46–8.
14.
RusthovenE., van der VlugtM.E., van Lingen-van BuerenL.J., van SchaijkT.C., WillemsH.L., MonnensL.A.Evaluation of intraperitoneal pressure and the effect of different osmotic agents on intraperitoneal pressure in children.Perit Dial Int2005; 25: 352–6.
15.
RusthovenE., KredietR.T., WillemsH.L., MonnensL.A., SchroderC.H.Peritoneal transport characteristics with glucose polymer-based dialysis fluid in children.J Am Soc Nephrol2004; 15: 2940–7.
16.
GerantonF., ChantrelF., BouillerM., MullerS., KolbI., MoulinB.Prediction of colloid osmotic pressure in renal patients.Clin Nephrol2000; 53: 269–75.
17.
DuncanA., YoungD.S.Measurements of serum colloid osmotic pressure are of limited usefulness.Clin Chem1982; 28: 141–5.
18.
WeisbergH.F.Osmotic pressure of the serum proteins.Ann Clin Lab Sci1978; 8: 155–64.
19.
KoningsC.J., KoomanJ.P., SchonckM., GladziwaU., WirtzJ., Van Den Wall BakeA.W.Effect of icodextrin on volume status, blood pressure and echocardiographic parameters: a randomized study.Kidney Int2003; 63: 1556–63.
20.
DaviesS.J., Garcia LopezE., WoodrowG., DonovanK., PlumJ., WilliamsP.Longitudinal relationships between fluid status, inflammation, urine volume and plasma metabolites of icodextrin in patients randomized to glucose or icodextrin for the long exchange.Nephrol Dial Transplant2008; 23: 2982–8. Epub 2008 May 2.
21.
Garcia-LopezE., WerynskiA., HeimburgerO., FilhoJ.C., LindholmB., AnderstamB.Rate of synthetic oligosaccharide degradation as a novel measure of amylase activity in peritoneal dialysis patients.Perit Dial Int2008; 28: 296–304.
22.
LamM.F., TseK.C., YipP.S., LuiS.L., ChanT.M., LoW.K.Retroperitoneal leakage as the cause for acute ultrafiltration failure and its associated risk factors in peritoneal dialysis.Perit Dial Int2008; 28(Suppl 4): S7.