HalesS.A method of conveying liquor into the abdomen during the operation of tapping. Letter to Cromwell Mortimer, Feb 22, 1744. London, England: Library of the Royal Society of Medicine.
2.
IbertiT.J., LieberC.E., BenjaminE.Determination of intra-abdominal pressure using a transurethral bladder catheter: Clinical validation of the technique.Anesthesiology1989; 70: 47–50.
3.
SugrueM., BuistM.D., LeeA., SanchezD.J., HillmanK.M.Intra-abdominal pressure measurement using a modified nasogastric tube: Description and validation of a new technique.Intensive Care Med1994; 20: 588–90.
RusthovenE., van der VlugtM.E., van Lingen-van BuerenL.J., van SchaijkTCJG, WillemsH.L., MonnensL.A.H.Evaluation of intraperitoneal pressure and the effect of different osmotic agents on intraperitoneal pressure in children.Perit Dial Int2005; 25: 352–6.
6.
OlindeA.J., CarpenterD., MaherJ.M.Tension pneumoperitoneum. A cause of acute aortic occlusion.Arch Surg1983; 118: 1347–50.
UnoT., HaradaY., KawarasakiH.Experimental study on the changes in circulatory kinetics due to an increase of intraabdominal pressure: The effective monitoring of the pressure of inferior vena cava.Nippon Geka Gakkai Zasshi1989; 90: 1685–91.
9.
KnolmeyerT.J., BowyerM.W., EganJ.C., AsbunH.J.The effects of pneumoperitoneum on gastric blood flow and traditional hemodynamic measurements.Surg Endosc1998; 12: 115–18.
10.
BloomfieldG.L., RidingsP.C., BlocherC.R., MarmarouA., SugermanH.J.A proposed relationship between intra-abdominal, intrathoracic, and intracranial pressure.Crit Care Med1997; 25: 496–503.
11.
RosenthalR.J., HiattJ.R., PhillipsE.H., HewittW., DemtriouA.A., GrodeM.Intracranial pressure. Effects of pneumoperitoneum in a large-animal model.Surg Endosc1997; 11: 376–80.
BerkowitzK.A., ButenskyM.S., SmithR.L.Pulmonary function changes after large volume paracentesis.Am J Gastroenterol1993; 88: 905–7.
14.
NagralA., KolhatkarV.P., BhatiaS.J., TaskarV.S., AbrahamP.Pulmonary function tests in cirrhotic and non-cirrhotic portal hypertension.Indian J Gastroenterol1993; 12: 36–40.
15.
AngueiraC.E., KadakiaS.C.Effects of large volume paracentesis on pulmonary function in patients with tense cirrhotic ascites.Hepatology1994; 20: 825–8.
16.
DurandP.Y., ChanliauJ., GambéroniJ., HestinD., KesslerM.APD: Clinical measurement of the maximal acceptable intraperitoneal volume.Adv Perit Dial1994; 10: 63–7.
17.
OdriozolaJ., BahlmannJ., FabelH.Einfluss der peritoneale dialyse auf die lungenfunktion.Klin Wochenschr1971; 49: 484–8.
18.
BerlyneG.M., LeeH.A., RalstonA.J., WoolcockJ.A.Pulmonary complications of peritoneal dialysis.Lancet1966; 2: 75–8.
19.
WadhwaN.K., SeligerM., GreenbergH.E., BergofskyE., MendelsonW.B.Sleep related disorders in end-stage renal disease patients on peritoneal dialysis.Perit Dial Int1992; 12: 51–6.
GotloibL., MinesM., GarmozoL., VarkaI.Hemodynamic effects of increasing intra-abdominal pressure in peritoneal dialysis.Perit Dial Bull1981; 1: 41–3.
22.
FischbachM., TerzicJ., LaugelV., EscandeB., DangelserC., HelmstetterA.Measurement of hydrostatic intraperitoneal pressure: A useful tool for the improvement of dialysis dose prescription.Pediatr Nephrol2003; 18: 976–80.
23.
ArandaR.A., Romao JuniorJ.E., KakehashiE., DomingosW., SabbagaE., MarcondesM.Intraperitoneal pressure and hernias in children on peritoneal dialysis.Pediatr Nephrol2000; 14: 22–4.
24.
HarrisK.P., KeoghA.M., AldersonL.Peritoneal dialysis fill volume: Can the patient tell the difference?Perit Dial Int2001; 21(Suppl 3): S144–7.
25.
ScanzianiR., DozioB., BaragettiI., MaroniS.Intraperitoneal hydrostatic pressure and flow characteristics of peritoneal catheters in automated peritoneal dialysis.Nephrol Dial Transplant2003; 18: 2391–8.
26.
FischbachM., TerzicJ., DangelserC., SchneiderP., RogerM.L., GeisertJ.Effect of posture on intraperitoneal pressure and peritoneal permeability in children.Pediatr Nephrol1998; 12: 311–14.
27.
FischbachM., TerzicJ., MenouerS., BergereV., FerjaniL., HaraldssonB.Impact of fill volume changes on peritoneal dialysis tolerance and effectiveness in children.Adv Perit Dial2000; 16: 321–3.
28.
VenturaM.D.J., AmatoD., Correa-RotterR., PaniaguaR.Relationship between fill volume, intraperitoneal pressure, body size, and subjective discomfort perception in CAPD patients. Mexican Nephrology Collaborative Study Group.Perit Dial Int2000; 20: 188–93.
29.
FischbachM., TerzicJ., ChauvéS., LaugelV., MullerA., HaraldssonB.Effect of peritoneal dialysis fluid composition on peritoneal area available for exchange in children.Nephrol Dial Transplant2004; 19: 925–32.
30.
DurandP.Y., ChanliauJ., GambéroniJ., HestinD., KesslerM.Intraperitoneal pressure, peritoneal permeability and volume of ultrafiltration in CAPD.Adv Perit Dial1992; 8: 22–5.
31.
DurandP.Y., ChanliauJ., GambéroniJ., HestinD., KesslerM.Hydrostatic intraperitoneal pressure and volume of ultrafiltration in CAPD.Adv Perit Dial1993; 9: 46–8.
32.
ImholzA.L.T., KoomenG.C.M., StruijkD.G., AriszL., KredietR.T.Effect of an increased intraperitoneal pressure on fluid and solute transport during CAPD.Kidney Int1993; 44: 1078–85.
33.
AbensurH., RomaoJ.E., De Almeida PradoE.B., KakehashiE., SabbagaE., MarcondesM.Influence of hydrostatic intraperitoneal pressure and the cardiac function on the lymphatic absorption rate of the peritoneal cavity in CAPD.Adv Perit Dial1993; 9: 41–5.
34.
ZakariaE.L.R., RippeB.Peritoneal fluid and tracer albumin kinetics in the rat. Effects of increases in intraperitoneal hydrostatic pressure.Perit Dial Int1995; 15: 118–28.
35.
FlessnerM.F., SchwabA.Pressure threshold for fluid loss from the peritoneal cavity.Am J Physiol1996; 270: F377–F390.
36.
ZinkJ., GreenwayC.V.Control of ascites absorption in anesthetized cats: Effects ofintraperitoneal pressure, protein, and furosemide diuresis.Gastroenterology1973; 73: 1119–24.
37.
FlessnerM.F.Transport of protein in the abdominal wall during intraperitoneal therapy. I. Theoretical approach.Am J Physiol Gastrointest Liver Physiol2001; 281: G424–37.
38.
KredietR.T., DoumaC.E., Van OldenR.W., Ho-dac-PannekeetM.M., StruijkD.G.Augmenting solute clearance in peritoneal dialysis.Kidney Int1998; 54: 2218–25.
39.
FischbachM., TerzicJ., GauglerC., BergereV., MunchK., HamelG.Impact of increased intraperitoneal fill volume on tolerance and dialysis effectiveness in children.Adv Perit Dial1998; 14: 258–64.
40.
KredietR.T., BoeschotenE.W., StruijkD.G., AriszL.Differences in the peritoneal transport of water, solutes and proteins between dialysis with two- and with three-liter exchanges.Nephrol Dial Transplant1988; 3: 198–204.
41.
TwardowskiZ.J., NolphK.D., ProwantB.F., MooreH.L.Efficiency of high volume low frequency continuous ambulatory peritoneal dialysis.ASAIO Trans1983; 29: 53–7.
42.
WangT., HeimburgerO., ChengH.H., WaniewskiJ., BergströmJ., LindholmB.Effect of increased dialysate fill volume on peritoneal fluid and solute transport.Kidney Int1997; 52: 1068–76.
43.
BrandesJ.C., PackardW.J., WattersS.K., FritscheC.Optimization of dialysate flow and mass transfer during automated peritoneal dialysis.Am J Kidney Dis1995; 25: 603–10.