Rutkow, I.C. "Orthopaedic Operations in the United State, 1979 through 1983," J.B.J.S., 68A:716-719 (1986).
2.
Stauffer, R.N. "Ten Year Follow-Up Study of Thtal Hip Replacement ," J.B.J.S., 64A:983-990 (1982).
3.
Sutherland, C.J., A. H.Wilde, L.S. Borden and K.E. Marks. "A Ten Year Follow-Up of 100 Consecutive Muller Curved Stem Total Hip Replacement Arthroplasties ," J.B.J.S., 64A:970-982 (1982).
4.
Lee, A.J.C. and R.S.M. Ling."Loosening," in Complications of Total Hip Replacement . R. S. M. Ling, ed. Edinburgh:Churchill Livingstone, 110-145 (1984).
5.
Volatile, T.B., F.C. Ewald, R.J. Friedman, E. Gebhardt, W.H. Thomas and C.B. Sledge. ''Ten Year Results of 139 Duocondylar Total Knee Replacements ," presented at 1986A.A.O.S., New Orleans.
6.
Ritter, M.A. , R.L. Thornberry and J.M. Silber. "Total Knee Replacement and Total Hip Replacement: A Comparison of Results," ContemporaryOrthopaedics, 10:73-77 (1985).
7.
Ewald, F.C., P. S. Walker, H.P.Hsu, O.Umatsu, K.M. Kelley and C.B. Sledge. "Is Total Knee Replacement Better Than Total Hip Replacement; ' Department of Orthopaedic Surgery, Brigham and Women's Hospital, Boston (private communication).
8.
Elson, R.A."Complications of the Wound," in Complications of Total Hip Replacement. R. S. M. Ling, ed. Edinburgh: Churchill-Livingstone, 41-57 (1984).
9.
Charnley, J.Acrylic Cement in Orthopaedic Surgery. Baltimore: The Williams and Wilkins Co., Chapter 1 (1970).
10.
Dumbleton, J.H. and J. Black. "Some Long-Term Complications;' in Complications of Total Hip Replacement. R. S. M. Ling, ed. Edinburgh: Churchill-Livingstone, 212-230 (1984).
11.
Dumbleton, J.H.Tribology of Natural and Artificial Joints. Amsterdam: Elsevier (1981).
12.
McKellop, H.A. and I.C. Clarke. "Evolution and Evaluation of Materials Screening Machines and Joint Simulators in Predicting in vivo Wear Phenomena ," in Functional Behavior of Orthopaedic Materials, Vol. II. D. Williams, ed. Boca Raton:C.R.C., Chapter 3, 51-85 (1985).
13.
Wroblewski, B.M. "15-21 Year Results of the Charnley Low-Friction Arthroplasty," Clinical Orthopaedics and Related Research , 211:30-35 (1986).
14.
Wroblewski, B.M. "Direction and Rate of Socket Wear in Charnley Low-Friction Arthroplasty," J.B.J.S., 67B:757-761 (1985).
15.
Atkinson, J.R. , D. Dowson, J.H. Isaac and B.M. Wroblewski. "Laboratory Wear Tests and Clincial Observations of the Penetration of Femoral Heads into Acetabular Cups in Total Replacement Hip Joints," Wear, 104:225-244 (1985).
16.
Buchhorn, U. , H.-G. Willert, M. Semlitsch and H. Weber. "Dimensionsanderungen der polyäthylen-Huftpfannen bei Müller-Hüftenprothesen," Z. Orthop., 122:127-135 (1984).
17.
Ziller, R., T. Uhlich, S. Blumentritt and P. Manner. "Röntgenologische Verschleissmessung an der Polyäthylenpfanne bei Hüfttotalendoprothesen," Beitr. Orthop. Traumatol., 32:290-296 (1985).
18.
Fukubayashi, T. and T. Tateishi. "Retrieval Analyses of the Total Hip Prostheses," Jpn. J. Artif. Organs, 13:1122-1125 (1984).
19.
Atkinson, J.R. , D. Dowson, G.H. Isaac and B.M. Wroblewski. "Laboratory Wear Tests and Clinical Observations of the Penetration of Femoral Heads into Acetabular Cups in Total Replacement Hip Joints," Wear, 104:217-224 (1985).
20.
Rose, R.M., A. Crugnola, M.Ries, W.R.Cimino, I.Paul and E.L. Radin. "On the Origins of High in vivo Wear Rates in Polyethylene Components of Total Joint Prostheses;' Clinical Orthopaedics and Related Research, 145:277-286 (1979).
21.
Rose, R.M. and E.L. Radin. "Wear of Polyethylene in the Total Hip Prosthesis," Clinical Orthopaedics and Related Research, 170:107-115 (1982).
22.
Rose, R.M., A. Crugnola, W.R. Cimino and M.D. Ries. "The in vivo Performance of Polyethylene Components of Total Joint Replacements;' in Implant Retrieval: Material and Biological Analysis. N.B.S. Special Publication 601, Washington, DC:U.S. Government Printing Office, 3-25 (1981).
23.
Ungethum, M. and W. Winkler-Gniewek . "Untersuchung des Verschleisses an Polyathylenkomponenten von Endoprothesen nach Klinischen Einsatz," Z. Orthop., 121:683-692 (1983).
24.
Plitz, W. and P. Griss. "Clinical, Histo-Morphological and Material Related Observations on Removed Alumina-Ceramic Hip Joint Components," in Implant Retrieval: Material and Biological Analysis. N.B.S. Special Publication 601, Washington, DC:U. S. Government Printing Office, 131-146 (1981).
25.
Boutin, P. and D. Blanquaert. "A Study of the Mechanical Properties of Alumina-on-Alumina Total Hip Prosthesis;' Rev. Chir. Orthop., 67:279-287 (1981).
26.
Griss, P. and G. Heimke. "Five Years' Experience with Ceramic-Metal-Composite Hip Endoprostheses. I. Clinical Evaluation," Archives of Orthopaedic and Traumatic Surgery, 98:157-164 (1981).
27.
Heimke, G. and P. Griss. "Five Years' Experience with Ceramic-Metal Composite Hip Endoprostheses. II. Mechanical Evaluation and Improvements," Archives of Orthopaedic and TraumaticSurgery, 98:165-171 (1981).
28.
Plitz, W., A. Walter andM. Jäger. "Materialspezifische Verschleisserscheinungen der Gleitpaarung Keramik/Keramik bei Revidierten Hüftendoprothesen-Klinische und Werkstoffkundliche Betrachtungen ," Zeitschrift für Orthopadie, 122:299-303 (1984).
29.
Rose, R.M., H.J. Nusbaum, H. Schneider, M. Ries, I.Paul, A.Crugnola, S.R. Simon and E.L. Radin. "On the True Wear Rate of Ultra High-Molecular-Weight Polyethylene in the Total Hip Prosthesis," J.B.J.S., 62A: 537-549 (1980).
30.
Hastings, G.W. "In vivo Wear Properties of Ultra-High Molecular Weight Polyethylene Used in a Total Knee Prosthesis," Wear , 55:1-9 (1979).
31.
Hood, R.W., T.M. Wright, A.H. Burstein and J.N. Insall. "Retrieval Analysis of Fifty-Seven Total Condylar Knee Prostheses," 27th Annual O.R.S, Las Vegas, Nevada, 159 (1981).
32.
Wright, T.M. , R.W. Hood and A.H. Burstein. "Analysis of Materials Failures," The Orthopaedic Clinics of North America, 13:33-44 (1982).
33.
Hood, R.W., T.M. Wright andA.H. Burstein. "Retrieval Analysis of Total Knee Prostheses: A Method and Its Application to 48 Total Condylar Prostheses," J. Biomed. Mater. Res., 17:829-842 (1983).
34.
Landy, M. and P.S. Walker. "Wear in Condylar Replacement Knees-A 10-Year Follow-Up ," 31st Annual O.R.S., Las Vegas, Nevada, 96 ( 1985).
35.
Wright, T.M. and D.L. Bartel. "The Problem of Surface Damage in Polyethylene Total Knee Components," Clinical Orthopaedics and Related Research, 205:67-74 (1986).
36.
Rose, R.M., M.D. Rise, I.L. Paul, A.M. Crugnola and E. Ellis. "On the True Wear Rate of Ultrahigh Molecular Weight Polyethylene in the Total Knee Prosthesis," J. Biomed. Mater. Res., 18:207-224 (1984).
37.
Hood, R.W., T.M. Wright, T. Fukubayashi and A.H. Burstein. "Contact Area and Pressure Distribution in Contemporary Total Knee Designs," 27th Annual O.R.S., Las Vegas, Nevada, 181 (1981).
38.
Pappas, M.J., G. Makris and F.F. Buechel. "Contact Stresses in Metal-Plastic Total Knee Replacements: A Theoretical and Experimental Study;' Biomedical Engineering Technical Report , #003, New Jersey Institute of Technology, Newark, NJ (1986).
39.
Bartel, D.L., A.H. Burstein, M.D. Toda and D.L. Edwards. "The Effect of Conformity and Plastic Thickness on Contact Stresses in Metal-Backed Plastic Implants," J. of Biomechanical Engineering, 107:193-199 (1985).
40.
Bartel, D.L., V.L. Bicknell and T.M. Wright. "The Effect of Conformity, Thickness and Material on Stresses in Ultra-High Molecular Weight Components for Total Joint Replacement," J.B.J.S., 68A:1041-1051 (1986).
41.
Wright, T.M. , T. Fukubayashi and A.H. Burstein. "The Effect of Carbon Fiber Reinforcement on Contact Area, Contact Pressure and Time-Dependent Deformation in Polyethylene Tibial Components," J. Biomed. Mater: Res., 15:719-730 (1981).
42.
Connelly, G.M. , C.M. Rimnac, T.M. Wright, R.W. Hertzberg and J.A. Manson. "Fatigue Crack Propagation Behavior of Ultrahigh Molecular Weight Polyethylene," J. Orthopaedic Research, 2:119-125 (1984).
43.
Wright, T.M., D.L. Bartel and C.M. Rimnac. "Carbon Fiber-Reinforced UHMWPE for Total Joint Replacement Components," 1st International Conference on Composites in Biomedical Engineering, London, 29-30 November (1985).
44.
Hood, R.W., T.M. Wright, A.H. Burstein and J.N. Insall. "Retrieval Analysis of Twenty Polyethylene Patellar Buttons ," 27th Annual O.R.S, Las Vegas, Nevada, 210 ( 1981).
45.
Hayes, W.C. and D.M. Levine. "Finite Element Analysis of Patellar Resurfacing Procedures ," 26th Annual O.R.S, 163 (1980).
46.
Willert, H.G. , G. Buchhorn and M. Semlitsch. "Recognition and Identification of Wear Products in the Surrounding Tissues of Artificial Joint Prostheses," in Tribology of Natural and Artificial Joints. J. H. Dumbleton, ed. Amsterdam: Elsevier, 381-419 (1981).
47.
Charnley, J. , A. Kamanger and M.D. Longfield. "The Optimum Size of Prosthetic Heads in Relation to the Wear of Plastic Sockets in Total Replacement of the Hip ," Med. and Biol. Engrg., 7:31-39 (1969).
48.
Webb, P.J., K.W.J. Wright and G.D. Winter. "The Monk 'Soft Top' Endoprosthesis," J.B.J.S., 62B:174-179 (1980).
49.
Vernon-Roberts, B. and M.A.R. Freeman. "Morphological and Analytical Studies of the Tissues Adjacent to Joint Prostheses: Investigations into the Causes of Loosening of Prostheses;' in Advances in Artificial Hip and Knee Joint Technology. M. Schaldach et al., eds. Berlin:Springer-Verlag, 148-186 (1976).
50.
Revell, P.A. "Tissue Reactions to Joint Prostheses and the Products of Wear and Corrosion," in Bone and Joint Disease. C. L. Berry, ed. Berlin: Springer-Verlag , 73-101 (1982).
51.
Eftekhar, N.S. , S.B. Doty, A.D. Johnston and M.V. Parisien. "Prosthetic Synovitis," in The Hip (Proceedings of the Hip Society). R. H. Fitzgerald, Jr., ed. St. Louis: Mosby, Chapter 13, 169-183 (1985).
52.
Willert. H. G. and M. Semlitsch. "Problems Associated with the Cement Anchorage of Artificial Joints," in Advances in Artificial Hip and Knee Joint Technology. M. Schaldach et al., eds. Berlin:Springer-Verlag , 325-346 (1976).
53.
Jasty, M.J., W.E. Floyd, III, A.L. Schiller, S.R. Goldring and W.H. Harris. "Localized Osteolysis in Stable Non-Septic Total Hip Replacement ," J.B.J.S., 68A:912-919 (1986).
54.
Kusy, R.P. and J.Q. Whitley. "Molecular Weight of a Bulk Ultra-High Molecular Weight Polyethylene Product-Impax 5M + UHMW-NAT," J. Biomed. Mater. Res., 20:1373-1389 (1986).
55.
Crugnola, A.M. , E.L. Radin, R.M. Rose, I.L. Paul, S.R. Simon and M.B. Berry. "Ultrahigh Molecular Weight Polyethylene as Used in Anticular Prostheses (A Molecular Weight Distribution Study)" J. Appl. Poly. Sci., 20:809-812 (1976).
56.
Ritter, M.A. and C. Barkley. "Low Molecular Weight Polyethylene: Cause for Wear in a Total Hip Replacement Case," Orthopaedic Review , XV:79-83 (1986).
57.
Rose, R.M., H.V. Goldfarb, E. Ellis and A.M. Crugnola. "On the Pressure Dependence of the Wear of Ultrahigh Molecular Weight Polyethylene," Wear, 92:99-111 (1983).
58.
Rostoker, W. and J.O. Galante. "Contact Pressure Dependence of Wear Rates of Ultra High Molecular Weight Polyethylene," J. Biomed. Mater: Res., 13:957-964 (1979).
59.
Heller, M., J. Schatzker and S.B. Goodman. "Fracture of a Polyethylene Acetabular Cup: A Case Report ;' The Canadian Journal of Surgery, 29: 48-49 (1986).
60.
Rose, R.M., E.V. Goldfarb, E. Ellis and A.N. Crugnola. "Radiation Sterilization and the Wear Rate of Polyethylene ," Journal of Orthopaedic Research, 2:393-400 (1984).
61.
Eyerer, P. and Y.C. Ke. "Property Changes of UHMW Polyethylene Hip Cup Endoprostheses During Implantation," J. Biomed. Mater: Res., 18: 1137-1151 (1984).
62.
Eyerer, R. "Property Changes of UHMW Polyethylene During Implantation-First Hints for the Development of an Alternative Polyethylene," 11th Annual Meeting of the Society for Biomaterials, San Diego, CA, 184 (1985).
63.
Eyerer, P., M. Kurth, H.A. McKellop and T. Mittlmeier. "Characterization of UHMWPE Hip Cups Run on Joint Simulators ," J. Biomed Mater: Res., 21:275-291 (1987).
64.
Kurth, M. and R. Eyerer. "Material Improvements of UHMWPE," European Biomaterials Society Meeting, Bologna, Italy, 215 (1986).
65.
Grobbelaar, C.J., T.A. DuPlessis and F. Marais. "The Radiation Improvement of Polyethylene Prostheses;' J.B.J.S., 60B:370-374 (1978).
66.
Atkinson, J.R. and R.Z. Cicek. "Silane Crosslinked Polyethylene for Prosthetic Application. II. Creep and Wear Behavior and a Preliminary Moulding Test," Biomaterials, 5:326-335 (1984).
67.
Heller, M., P. Christel and L. Sedel. "Tissue Tolerance to Irradiated-PTFE-Grafted Polyethylene ," European Biomaterials Society Meeting, Bologna, Italy, 143 (1986).