Abstract
Zeolite is a multifunctional material, which recently exhibited promising prospects in emerging biological and medical applications. This study reported a new bio-inorganic hybrid of zeolite-fibrin clot composite serving as haemostatic agent in haemophilia A. The zeolite-fibrin clot composite promoted haemocompatibility and helped to achieve short clotting time both in vitro (22 ± 3 s vs. >600 s) and in vivo (4.5 min vs. >60 min) compared to control in coagulation factor VIII deficiency bleeding model. Therefore, in situations of surgical operation or accidental injury, this effective and ready-to-use haemostatic agent may provide rapid haemostasis for haemophilia A patients.
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.