Galbraith S. , Teasdale G.Predicting the need for operation in the patient with occult traumatic haematomaJ Neurosurg1991,5575-81
2.
Hauerberg J. , Juhler M.Cerebral blood flow in acute intracranial hypertensionJ Cereb Blood Flow Metab1994 ,14519-525
3.
Morgalla MH, Krasznai L., Buchholz R., et al Repeated decompressive craniectomy after head injury in children two successful cases as result of improved neuromonitoringSurg Neurol1995;43583-590
4.
Allen R.Intracranial pressure a review of clinical problems, measurement techniques and monitoring methodsJ Med Eng Technol1986 ,10299-320
5.
Chambers KR, Kane PJ, Choksey MS, et al An evaluation of the Cammo ventricular bolt system in clinical practiceNeurosurgery1993,33.866-868
6.
Gambardella G., d'Avella D., Tomasello F.Monitoring of brain tissue pressure with a fibreoptic deviceNeurosurgery1992, 31918-921
7.
Rosner MJ, Becker DPICP monitoring complications and associated factorsClin Neurosurg1976,23494-519
Miller JD, Becker P., Ward J.Significance of intracranial hypertension in severe head injuryNeurosurgery1977,47503-516
10.
Morgalla MH , Cuno M., Mettenleiter H., et al ICP monitoring with a re-usable transducer experimental and clinical evaluation of the gaeltec ICT/b pressure probeActa Neurochir (Wien) 1997,139569-573
11.
Morgalla MH , Mettenleiter H., Katzenberger T., et al ICP measurement accuracy the effect of temperature drift Design of a laboratory test for assessment of ICP transducersJ Med Eng Technol1999 ,2310-14
12.
Johnston IH , Rowan JORaised intracranial pressure and cerebral blood flow intracranial pressure gradients and regional cerebral blood flowJ Neurol Neurosurg Psychiatry1974,37:585-592
13.
Robmet K.Increased intracranial pressure management with an intraventricular catheterJ Neurosurg Nurs1985,1795-104
14.
Trevisani GT , Shackford SR, Zhuang J., et al Brain edema formation after brain injury, shock and resuscitation effects of venous and arterial pressureJ Trauma1994,37452-458
15.
Weinstabl C. , Richling B., Plainer B., et al Comparative analysis between epidural (Gaeltec) and subdural (Camino) intracranial pressure probesJ Clin Monit1992,8116-120
16.
Price DJ, Hille PT, Mason J.Evaluation of a fiberoptic system for monitoring of ventricular pressure In Hoff JT, Betz AL, eds Intracranial pressure VIIBerlinSpringer, 198952-54
17.
Stangl AP , Meyer B., Zentner J., et al Continuous external CSF dramage—a perpetual problem in neurosurgerySurg Neurol1998,50:77-82
18.
Aucom P., Kotilainen H., Gantz N.Intracranial pressure monitors epidemiologic study of risk factors and infectionsAm J Med1986,80369-376
19.
Rieger A., Schon R.Zum Problem der Infektion der HirnventrikeldruckmessungenZentralbl Chir1989,114530-533
20.
Tronnier V. , Aschoff A., Hund E., et al Commercial external ventricular sets unsolved safety and related problemsActa Neurochir1991,11049-56