Abstract
Background
Thromboelastography (TEG) can guide transfusion therapy in trauma and has been associated with decreased transfusion requirements. This population differs from the medical population where the most common bleeding source is gastrointestinal hemorrhage (GIB). The utility of TEG in patients with acute GIB is not well described. We sought to assess whether the use of TEG impacts blood product utilization in patients with medical GIB.
Methods
A retrospective study looking at all adult patients admitted with a primary diagnosis of GIB to the George Washington University Intensive Care Unit (ICU) between 01/01/2017 to 12/31/2019. The primary intervention was the use of TEG to guide blood product resuscitation in addition to standard of care (TEG arm) versus standard of care alone (non-TEG arm).
Results
The primary outcome was the total number of blood products utilized. Patients in the TEG arm used more blood products compared to the non-TEG arm (9.10 vs 3.60, p < 0.001). There was no difference in secondary endpoints except for an increased requirement for mechanical ventilation within the TEG arm (26.2% vs 13.4%, p = 0.018).
Conclusions
The use of TEG to guide resuscitation in patients with acute GIB may be associated with increased blood product utilization without any clinical benefit to patient-centered outcomes.
Get full access to this article
View all access options for this article.
References
Supplementary Material
Please find the following supplemental material available below.
For Open Access articles published under a Creative Commons License, all supplemental material carries the same license as the article it is associated with.
For non-Open Access articles published, all supplemental material carries a non-exclusive license, and permission requests for re-use of supplemental material or any part of supplemental material shall be sent directly to the copyright owner as specified in the copyright notice associated with the article.