Saxon, R.1986. "Atrium Buildings Development and Design," 2nd edition, Architectural Press- London.
2.
Morgan, H.P. and J.P. Gardner.1990. "Design Principles for Smoke Ventilation in Enclosed Shopping Centres," Building Research Establishment Report, Fire Research Station, Borehamwood, U.K.
3.
NFPA 92B. 1991. "Guide for Smoke Management Systems in Malls, Atria and Large Area," National Fire Protection Association, Quincy, Ma, U.S.A.
4.
Klote, J. and J. Milke.1992. "Design of Smoke Management Systems ," ASHRAE Publication 90022 ASHRAE, Atlanta, Georgia, U.S.A.
5.
Smith, F.M. and J.R. Barnfield.1990. "Guide to Smoke Extraction in Buildings ," WFRC No. C49378 Warrington Fire Research Consultants -Cheshire, U.K.
6.
Tanaka, T. and T. Yamana.1985. "Smoke Control in Large Scale Spaces-Part 1," Fire Science and Technology, 5(1):31-40.
7.
Yamana, T. and T. Tanaka.1985. "Smoke Control in Large Scale Spaces-Part 2," Fire Science and Technology, 5(1):41-54.
8.
Waters, R.A.1989. "Stansted Terminal Building and Early Atrium Studies," Journal of Fire Protection Engineering , 1:63-76.
9.
Mitler, H.E.1990. "Mathematical Modelling of Enclosure Fires," NISTIR 90-4294, Building and Fire Research Laboratory, National Institute of Standards and Technology, Gaitherburg, Maryland , U.S.A.
10.
Friedman, R.1991. "Survey of Computer Models for Fire and Smoke," Forum for International Cooperation on Fire Research, Factory Mutual Research Corporation, Norwood, Ma 02062, U.S.A.
11.
Peacock, R.D. , S. Davis and B.T. Lee.1988. "An Experimental Data Set for the Accuracy Assessment of Room Fire Models," NBSIR 88-3752, National Bureau of Standards-Gaithersburg, Maryland , U.S.A.
12.
Duong, D.Q.1990. "The Accuracy of Computer Fire Models: Some Comparisons with Experimental Data from Australia," Fire Safety Journal, 16:415-431.
13.
Hägglund, B. "Comparing Fire Models with Experimental Data ," FOA Report C20864-24, National Defence Research Establishment , Sundbyberg, Sweden.
14.
Peacock, R.D. , W.W. Jones and R.W. Bukowski.1990. "Verification of a Model of Fire and Smoke Transport," Fire Safety Journal , 21:89-129.
15.
Chow, W.K. and W.K. Wong.1993. "On the Simulation of Atrium Fire Environment in Hong Kong Using Zone Models," Journal of Fire Sciences , 11(1):3-51.
16.
Mitler, H.E. and J.A. Rockett.1987. "User's Guide to FIRST: A Comprehensive Single-Room Fire Model," NBSIR 87-3595, Centre for Fire Research, National Bureau of Standards, Gaithersburg, Maryland, U.S.A.
17.
Peacock, R.D. , G.P. Forney, P. Reneke, R. Portier and W.W. Jones.1993. " CFAST, the Consolidated Model of Fire Growth and Smoke Transport," NIST Technical Note 1299, NIST, U.S. Dept. of Commerce, Maryland, U.S.A.
18.
Cooper, L.Y. and G.P. Forney.1990. "The Consolidated Compartment Fire Model (CCFM) Computer Code Application CCFM.VENTS—Part 1: Physical Basis " NISTIR 4342, National Institute of Standards and Technology , Gaithersburg, Maryland, U.S.A.
19.
Forney, G.P. and L.Y. Cooper.1990. "The Consolidation Compartment Fire Model (CCFM) Computer Code Application CCFM.VENTS—Part 2: Software Reference Guide," NISTIR 4343, National Institute of Standards and Technology, Gaithersburg, Maryland, U.S.A.
20.
Cooper, L.Y. and G.P. Forney.1990b. "The Consolidation Compartment Fire Model (CCFM) Computer Code Application CCFM.VENTS—Part 3: Software Reference Guide," NISTIR 4343, National Institute of Standards and Technology, Gaithersburg, Maryland, U.S.A.
21.
Forney, G.P. , L.Y. Cooper and W. Moss.1990. "The Consolidation Compartment Fire Model (CCFM) Computer Code Application CCFM.VENTS—Part 4: Software Reference Guide," NISTIR 4343, National Institute of Standards and Technology, Gaithersburg, Maryland, U.S.A.
22.
1990-1992. "FIRECALC-Fire Engineering Software," Division of Building, Construction and Engineering, CSIRONorth Ryde, Australia