A vertical riser fire test has been developed to evaluate cables for Classifica tion in accordance with the vertical fire spread requirements of the 1984 National Electrical Code. The test simulates a cable installation in a riser shaft with exposure to a large fire source. A variety of copper conductor cables and op tical fiber cables were tested. Some cables exhibited only minor flame propaga tion and are now Classified by Underwriters Laboratories for use in riser shafts.
Get full access to this article
View all access options for this article.
References
1.
Kaufman, S., Williams, J.L., Smith, E.E. and Przybyla, L.J., "Large Scale Fire Tests of Building Riser Cables,"Journal of Fire Sciences, Vol. 1, pp. 54-65 (January/February 1983).
2.
Przybyla, L.J. and Guida, T.J., Underwriters Laboratories Report on Telephone Cable-Classified for Flame Propagation (April 19, 1984).
3.
Dillow, H.M. and Dougherty, T.S., "New Color Coded Dual Insulated Riser Cables," Proceedings of the 30th International Wire and Cable Symposium 1981, pp. 318-323.
4.
Kaufman, S. and Landreth, C.A., "Development of Improved Flame Resistant Interior Wiring Cables," Proceedings of the 24th International Wire and Cable Symposium , pp. 9-14 (1975).
5.
Kaufman, S. and Yocum, M.M., "The Behaviour of Fire-Resistant Communications Cables in Large-Scale Fire Tests,"Plastics and Rubber: Materials and Applications , Vol. 4, No. 4, pp. 149-157 (November 1979).
6.
Arroyo, C.J. and Bursh, T.P., "Circuit Transmission Integrity of Plenum Cables in a Developing Fire Scenario," Proceedings of the 32nd International Wire and Cable Symposium , pp. 372-380 (1983).
7.
Loadholt, J.T. and Williamson, T.M., "Design of Fiber Optic Cables for Customer Premises Applications," Proceedings of the 33rd International Wire and Cable Symposium, pp. 357-364 (1984).
8.
National Fire Protection Association, 1984 National Electrical Code, Section 800-3(d).
9.
Underwriters Laboratories, UL 910 Standard for Test Method for Fire and Smoke Characteristics of Cable Used in Air-Handling Spaces.
10.
Beyreis, J.R. , Skjordahl, J.W., Kaufman, S. and Yocum, M.M., "A Test Method for Measuring and Classifying the Flame Spreading and Smoke Generating Characteristics of Communications Cable," Proceedings of the Twenty-Fifth International Wire and Cable Symposium, pp. 291-295 (1976).
11.
Williams, J.L. and Kaufman, S., "A Comparison of Cable Fire Tests," Proceedings of the International Conference on Fire Safety, Volume 9, pp. 166-181 (1984).