RoncoC., FabrisA., ChiararnonteS.Comparison of four different short hemodialysis techniques. Int J Artif Organs1988; 3: 169–74.
2.
RoncoC., FabrisA., ChiaramonteS.Impact of high blood flows on vascular stability in hemodialysis. Nephrol Dial Transplant1990; 1(suppl. 5): S109–14.
3.
ToichinDo. Acetate metabolism and high efficiency hemodialysis. Int J Artif Organs1979; 2: 1–6.
4.
RoncoC., FabrisA., FerianiM.Tedinical and clinical evaluation of a new system for ultrafiltration control during hemodialysis. Trans Am Soc Artif Intern Organs1988; 3: 613–5.
5.
BoschJ.P., von AlbertiniB., RoncoC.Hemofiltration and Hemodiafiltration. In: GlassockR.J., ed. Current therapy in nephrology and Hypertension 2.Toronto-Philadelphia: BC Decker Inc, 1987; 258–63.
6.
SantoroA., SponganoM., FerrariG., ZucchelliP.Analysis of the factors influencing bicarbonate balance during acetate free biofiltration. Kidney Int1993; 43(suppl. 41): S184–7, 1993.
7.
GhezziP.M., FrigatoG., FantiniG.F.Theoretical model and first clinical results of the paired filtration dialysis. Life Support Systems1983, (suppl. 1): S271–8.
8.
FerianiM., RoncoC., BiasiollS., BragantiniL., La GrecaG.Effect of dialysate and substitution fluid buffer on buffer flux in hemodiafiltrationKidney Int1991; 39: 711–7.
9.
CanaudB., ImbertE., KaakiM.Clinical and microbiological evaluation of a postdilutional hemofiltration system with inline production of substitution fluid. Blood Purif1990; 8: 160–70.
10.
RoncoC.Backfiltration in clinical dialysis: nature of the phenomenon, mechanisms and possible solutions. Int J Artif Organs1990; 13: 11–21.
11.
RoncoC., BrendolanA., CrepaldiC.Water and dialysate treatment for hemodialysis. In: Bosch, ed. Hemodialysis; high efficiency treatments.New York: Churchill Livingstone, 1993; 41–61.
12.
RoncoC., GhezziP.M., BrendolanA., CrepaldiC., La GrecaG.The haemocialysis system: basic mechanism of water and solute transport in excorporeal renal replacement therapies. Neph Dial Transplant1998; 13(suppl. 6): S3–9.
13.
BrendolanA., RoncoC., GhezziP.M., ScabardiM., La GrecaG.Hydraulic and flow-dynamic characteristics of PMMA dialyzers. Contrib Nephrol1998; 125: 41–52.
14.
RoncoC., ScabardiM., GoldoniM., BrendolanA., CrepaldiC., La GrecaG.Inpact of spacing filaments external to hollow fibers on dialysate flow distribution and dialyzer performance. Int J Artif Organs, 1997; 20: 261–6.
15.
RoncoC., OrlandiniG., BrendolanA., LupiA., La GrecaG.Enhancement of convective transport by internal filtration in a modified experimental hemodialyzer. Kidney Int1998; 54: 979–85.
16.
LowrieE.G., LairdN.M., ParkerT.F., SargentJ.A.Effect on the hemodialysis prescrjption on patient morbidity. N Engl J Med1981; 20: 1176–81.
17.
U.S. Renal Data System: USRDS 1991 Annual Data Report, Bethesda, MD, National Institutes of Health, National Institute of Diabetes and Digestive and Kidney Diseases, 1991, pp D.1–E.62.
LevinN.W., GotchF.A., DaugirdasJ.T., TeschanP.E., CollinsA.J., KeshaviahP.What is the role of Kt/V urea in chronic dialysis. Semin Dial1990; 3(2): 73–4.
20.
JindalK.K., ManuelA., GoldsteinM.B.Percent reduction of the blood urea concentration during hemodialysis (PRU), a simple and accurate method of estimate Kt/V urea. Trans Am Soc Artif Intern Organs1987; 33: 286–8.
21.
DaugirdasJ.T.Rapid methods of estimating Kt/V: three formulas compared. ASAIO Trans1990; 36: M362–M364.
22.
GarredL.J., CanaudB.C., McCreadyW.G.Optimal hemodialysis: the role of quantification. Semin Dial1994; 1(4): 236–45.
23.
SchneditzD., PolascheggH.D., LevinN.W.Caridopul-monary recirculation in dialysis. An underrecognized phenomenon. ASAJO J1992; M194–M196.
24.
SargentJ.A.Shortfalls in the delivery of dialysis. Am J Kidney Dis1990; 15: 500–10.
25.
DepnerT.A.Assessing adquacy of hemodialysis: urea modeling. Kidney Int1994; 45: 1522–35.
26.
PeticlercT., ManN.K., GoureauY., JepenneG., Funck-BrentanoJ.L.Optimization of sodium dialysate concentration by plasma water conductivity monitoring. In: NoséY., KjellestrandC., IvanovichP. eds. Progress in artificial organs, New York: ISAO Press, 1985.
27.
LocatelliF., Di FilippoS., ManzoniC.Monitoring sodium removal and delivered dialysis by conductivity. Int J Artif Organs1995; 18: 716–21.
KeshaviahP., EbbenJ., LuhvingD., EmmersonP.Clinical evaluation of new on-line monitor of dialysis adequacy. J Am Soc Nephrol1992, 3: 374.
30.
ThomasethK.PANSYM: a symbolic equation generation for mathematical modeling, analysis and control of metabolic and pharmacokinetic systems. Comput Meth Programs Biomed1994; 42: 99–112.
31.
ThavarungkulP., MakansonH., HolstO., MattiansonB.Continuous monitoring of urea in blood during dialysis. Biosensors and Bioelectronics1991; 6: 323–8.
DepnerT., CollinsA., Jindal. Multicenter clinical validation of an on-line urea monitor (Abstract). J Am Soc Nephrol1993; 4: 343–7.
34.
GarredL.S., AmourNrst, McCreadyW.G., CanaudB.C.Urea kinetic modelling with a prototype urea sensor in the spent dialysate stream. ASAIO J1993; 339: M337–341.
35.
StillerS., WrtU.D., WaterbarF., GladziwaU., DashnamurtyK.V., MannH.Less symptomatic hypotension using BV-controlled ultrafiltration. Trans Am Soc Artif Intern Organs1991; 37: 139–41.