Continuous ambulatory peritoneal dialysis was successfully carried out in 6 end-stage renal failure patients using self-made, ultrafiltration-sterilized dialysis solutions. A Y-set was used to deliver the above solutions to sterile plastic bags.
HendersonL.W., BeansE.. Successful production of sterile pyrogen-free electrolyte solution by ultrafiltration.Kidney Int1978; 14: 522–5.
2.
ChenW.T., NakamotoS., IngT.S., ThompsonK.D., SoungL.S.. Sterilization of parenteral fluids by ultrafiltration.Abst 2nd Annu Meet Int Soc for Artif Organs, April 18-19, New York, NY, 1979; 3: 6.
3.
LeberH.W., WizemannV., GoubeaudG., RawerP., SchutterleG.. Simultaneous hemofiltration/hemodialysis: an effective alternative to hemofiltration and conventional hemodialysis in the treatment of uremic patients.Clin Nephrol1978; 9: 115–21.
4.
ShaldonS., BeauM.C., DeschodtG.Three years of experience with on-line preparation of sterile pyrogen-free infusate for haemofiltration.Contr Nephrol1982; 32: 161–4.
5.
Von AlbertiniB., MillerJ.H., GardnerP.W., ShinabergerJ.. High-flux hemodiafiltration: under six hours/week treatment.Trans ASAIO1984; 30: 227–31.
6.
RindiP., PiloneN., RiccoV., CioniL.. Clinical experience with a new hemodiafiltration (HDF) system.Trans ASAIO1988; 34: 765–8.
7.
YuA.W., ManahanF.J., FilkinsJ.P.Peritoneal dialysis using bicarbonate-containing solution sterilized by ultrafiltration.Int J Artif Organs1991; 14: 463–5.
8.
IngT.S., YuA.W., ThompsonK.D.Peritoneal dialysis using conventional, lactate-containing solution sterilized by ultrafiltration.Int J Artif Organs1992; 11: 658–60.
9.
IngT.S., YuA.W., AgrawalB.Continuous ambulatory peritoneal dialysis using self-made, ultrafiltration-sterilized, L-lactate-based solution (abstract).J Am Soc Nephrol1994, in press.
10.
Technical datafrom Fresenius USA.
11.
SorkinMl. Apparatus for peritoneal dialysis. In: DaugirdasJ.T., IngT.S., eds. Handbook of Dialysis, 2nd ed.Little, Brown and Co, Boston, Massachusetts1994; 262–73.
ChaimovitzC., RapoportJ., ConfortiA., DouvdevaniA.. Commercial dialysis fluid causes intracellular acidosis in peritoneal macrophages (Mac) (Abstract).J Am Soc Nephrol1992; 3: 407.
16.
ZhouX.J., YuA.W., ZhouF.Q., RyuJ., IngT.S., VaziriN.D.. Effects of an acidic, lactate-based peritoneal dialysis solution and its euhydric, bicarbonate-based counterpart on neutrophilic intracellular pH.Int J Artif Organs1993; 16: 816–9.
17.
LiberekT., TopleyN., JorresA.Peritoneal dialysis fluid inhibition of polymorphonuclear leukocyte respiratory burst activation is related to the lowering of intracellular pH.Nephron1993; 65: 260–5.
18.
IngB.L., GuptaD.K., NawabZ.M., ZhouF.Q., RahmanM.A., DaugirdasJ.T.. Suppression of neutrophil superoxide production by conventional peritoneal dialysis solution.Int J Artif Organs1988; 11: 351–4.
19.
MooreA.L., GrantB.W., DorighiJ.A., BelinsonJ.L., StewartJ.A., AlbertiniR.J.. Effect of commercial peritoneal dialysis fluids on the lytic function of lymphokine-activated killer cells.J Biol Response Mod1988; 7: 401–8.
20.
KronerW., KotheH.. Discoloration of dextrose solutions.Ind Eng Chem1939; 31: 248.
21.
ShallenbergerR.S., BirchG.G.. Sugar chemistry.The Avi Publishing Co., Westport, Connecticut1975; 169–93.