SpencerF.C., EisemanB., TrinkleJ.K., RossiN.P.Assisted circulation for cardiac failure following intracardiac surgery with cardiopulmonary bypass.J Thorac Cardiovasc Surg1965; 49: 56–73.
2.
CooleyD.A., LiottaD., HallmannG.L., BloodwellR.D.First clinical implantation of a total artificial heart.Trans ASAIO1969; 15: 68–74.
3.
CopelandJ.G., LevinsonM.M., SmithR.The total artificial heart as a bridge to transplantation.JAMA1986; 256, 12: 2991–5.
4.
LericheR., FontaineR.Essai expérimental de traitement de certains infarctus du myocarde et de l'anévirsme du coeur par une greffe de muscle strié.Bull Soc Nat Chir1933; 59: 229–32.
5.
KantrowitzA., McKinnonW.M.P.The experimental use of the diaphragm as an auxilliary myocardium.Surg Forum1958; 9: 266–8.
6.
CarpentierA., ChachquesJ.C.Myocardial substitution with a stimulated skeletal muscle. First successful clinical case.Lancet1985; 1: 1267.
PortnerP.M., OyerP.E., PenningtonD.G.Implantable electric left ventricular assist system. Bridge to transplantation and the future.Ann Thorac Surg1989; 47: 142–50.
TrubelW., LosertU., SchimaH.Total artificial heart bridging: a temporary support for deteriorating HTX - candidates.Thor Cardiovasc Surg1987; 35(5): 277–82.
14.
PaeW.E., RosenbergG., DonachyJ.H.Mechanical circulatory assistance for postoperative cardiogenic shock: a three year experience.Trans Am Soc Artif Intern Organs1980; 26: 256–61.
15.
PaeW.E.International VAD registry - Hershey Medical Center.Division for Artificial Organs, Pennsylvania -USA.
16.
TermuhlenD.F., SwartzM.T., PenningtonD.G.Predictors for weaning patients from ventricular assist devices.Trans Am Soc Artif Intern Organs1988; XXXIV: 131–9.
CabrolC., LegerP.H., GandjbakhchI.Clinical application and patient selection in the use of a total artificial heart as a bridge for transplantation.Pacing and Clinical Electrophysiology1988; 11, 6 (II): 933–8.
19.
OlsenD.B., RiebmanJ.B., De PaulisR.Registry and tabulations of orthotopic total artificial hearts in humans.Trans Am Soc Artif Intern Organs1987; 32: 182–9.
20.
De VriesW.The permanent artificial heart.JAMA1988; 259, 6: 849–59.
21.
ChachquesJ.C., GrandjeanP., SchwarztK.Effect of latissimus dorsi dynamic cardiomyoplasty on ventricular function.Circulation1988; 78(5) (Suppl III): 203–16.
FarrarD.J., LitwakP., LawsonJ.H.In vivo evaluations of a new thromboresistant polyurethane for artificial heart blood pumps.J Thorac Cardiovasc Surg1988; 95: 191–200.
24.
PetersG.Plastikinfektionen der Staphylokokken.Dt Ärzteblatt1988; 85: 286.
25.
AnnasG.J.No cheers for temporary artificial hearts.Hastings Cent Rep1985; 15(5): 27–8.
26.
JoyceL.D., JohnsonK.E., PierceW.S.Summary of the world experience with clinical use of total artificial hearts as cardiac support devices.J Heart Transpl1986; 5: 229–35.