Vascular access is the Achilles’ heel of hemodialysis. Current vascular access approaches for hemodialysis include arteriovenous (AV) fistula, AV graft, and central venous catheter. Strengths and weaknesses of each access type are described. New technology and procedures in introducing an access, monitoring access function, and salvaging a non-functioning access are also described.
QuintonW., DillardD., ScribnerB.H.. Cannulation of blood vessels for prolonged hemodialysis.Trans Am Soc Artif Intern Organs1960; 6: 104–13.
2.
ShaldonS., SilvaH., PomeroyJ., RaeA.I., RosenS.M.. Percutaneous femoral venous catheterization and reusable dialysers in the treatment of acute renal failure.Trans Am Soc Artif Intern Organs1964; 10: 133–5.
3.
UldallR., DeBruyneM., BesleyM., McMillanJ., SimonsM., FrancoeurR.. A new vascular access catheter for hemodialysis.Am J Kidney Dis1993; 21: 270–7.
4.
BresciaM.J., CiminoJ.E., AppelK., HurwichB.J.. Chronic hemodialysis using venipuncture and a surgically created arteriovenous fistula.N Engl J Med1966; 275: 1089–92.
5.
KumarV., DepnerT., BesarabA., AnanthakrishnanS.. Arteriovenous access for hemodialysis. In: DaugirdasJ.T., BlakeP.G., IngT.S., eds. Handbook of Dialysis, 4th ed.Lippincott Williams & Wilkins, Philadelphia, PA; 2007. p 105–26.
6.
AstorB.C., CoreshJ., PoweN.R., EustaceJ.A., KlagM.J.. Relation between gender and vascular access complications in hemodialysis patients.Am J Kidney Dis2000; 36: 1126–34.
7.
AllonM., LockhartM.E., LillyR.Z., GallichioM.H., YoungC.J., BarkerJ.. Effect of preoperative sonographic mapping on vascular access outcomes in hemodialysis patients.Kidney Int2001; 60: 2013–20.
National Kidney Foundation-KDOQI Clinical practice guidelines for vascular access: Update 2006.Am J Kidney Dis2006; 48(Suppl 1): S248–73.
13.
KrivitskiN.M.. Theory and validation of access flow measurement by dilution technique during hemodialysis.Kidney Int1995; 48: 244–50.
14.
GrudzinskiL., QuinanP., KwokS., PierratosA.. Sodium citrate 4% locking solution for central venous dialysis catheters - an effective, more cost-efficient alternative to heparin.Nephrol Dial Transplant2007; 22: 471–6.
15.
McGillR., SperoJ., SysakJ., SandroniS., MarcusR.. Tissue plasminogen activator as a hemodialysis catheter locking solution.Hemodial Int2008: (in press).
16.
Fernandez-HidalgoN., AlmiranteB., CallejaR., RuizI., PlanesA.M., RodriguezD.. Antibiotic-lock therapy for long-term intravascular catheter-related bacteraemia: Results of an open, non-comparative study.J Antimicrob Chemother2006; 57: 1172–80.
17.
TwardowskiZ.. Constant site (buttonhole) method of needle insertion for hemodialysis.Dial Transplant1995; 24: 559–60.
18.
TomaS., ShinzatoT., FukuiH., NakaiS., MiwaM., TakaiI.. A timesaving method to create a fixed puncture route for the buttonhole technique.Nephrol Dial Transplant2003; 18: 2118–21.
19.
AstorB.C., EustaceJ.A., PoweN.R., KlagM.J., SadlerJ.H., FinkN.E.. Timing of nephrologist referral and arteriovenous access use: The CHOICE Study.Am J Kidney Dis2001; 38: 494–501.
20.
MillerC.D., RobbinM.L., AllonM.. Gender differences in outcomes of arteriovenous fistulas in hemodialysis patients.Kidney Int2003; 63: 346–52.
21.
MarcusR.J., MarcusD.A., SureshkumarK.K., HussainS.M., McGillR.L.. Gender differences in vascular access in hemodialysis patients in the United States: Developing strategies for improving access outcome.Gend Med2007; 4: 193–204.
22.
LiuZ., ZhuB., WangX., JingY., WangP., WangS.. Clinical studies of hemodialysis access through formaldehyde-fixed arterial allografts.Kidney Int2007; 72: 1249–54.
23.
RaggJ.L., TreacyJ.P., SnellingP., FlackM., AndertonS.. Confidence limits of arteriovenous fistula flow rate measured by the “On-line” thermodilution technique.Nephrol Dial Transplant2003; 18: 955–60.
24.
WijnenE., van der SandeF.M., KoomanJ.P., de GraafT., TordoirJ.H., LeunissenK.M.. Measurement of hemodialysis vascular access flow using extracorporeal temperature gradients.Kidney Int2007; 72: 736–41.
25.
VeselyT.M.. Role of stents and stent grafts in management of hemodialysis access complications.Semin Vasc Surg2007; 20: 175–83.
26.
VeselyT.M., AminM.Z., PilgramT.. Use of stents and stent grafts to salvage angioplasty failures in patients with hemodialysis grafts.Semin Dial2008; 21: 100–4.
27.
AshS., BrownK., AsifA., YevzlinS., SamahaA.. Preliminary clinical study of a self-centering central venous catheter for dialysis (Centros TM).Semin Dial2008; 21: 105–11.
28.
DavenportA., GuraV., RoncoC., BeizaiM., EzonC., RambodE.. A wearable haemodialysis device for patients with endstage renal failure: A pilot study.Lancet2007; 370: 2005–10.