HerrerosJ., BerjanoE.J., MasP.. Platelet dysfunction in cardiopulmonary bypass: An experimental comparative study between a centrifugal and a new pulsatile pump.Int J Artif Organs2003; 26: 1086–94.
2.
ÜndarA.. Myths and truths of pulsatile and non-pulsatile perfusion during acute and chronic cardiac support (Editorial).Artif Organs2004; 28: 439–43.
3.
ÜndarA.. The ABCs of research on pulsatile versus nonpulsatile perfusion during cardiopulmonary bypass (Editorial).Med Sci Monit2002; 8: ED21–ED24.
4.
WrightG.. Hemodynamic analysis could resolve the pulsatile blood flow controversy.Ann Thorac Surg1994; 58: 1199–204.
5.
ShepardR.B., SimpsonD.C., SharpJ.F.. Energy equivalent pressure.Arch Surg1966; 93: 730–40.
6.
ÜndarA., MasaiT., YangS.Q.. Effects of perfusion mode on regional and global organ blood flow in a neonatal piglet model.Ann Thorac Surg1999; 68: 1336–43.
7.
OrimeY., ShionoM., HataH.. Cytokine and endothelial damage in pulsatile and non-pulsatile cardiopulmonary bypass.Int J Artif Organs1999; 23: 508–12.
8.
ÖzatikM.A., TarcanO., KaleA.. Do S100ß protein level increases due to inflammation during cardiopulmonary bypass occur without any neurological deficit?Perfusion2002; 17: 335–8.
9.
MurkinJ.M., MartzkeJ.S., BuchanA.M., BentleyC., WongC.J.. A randomized study of the influence of perfusion technique and pH management strategy in 316 patients undergoing coronary artery bypass surgery. I. Mortality and cardiovascular morbidity.J Thorac Cardiovasc Surg1995; 110: 340–8.
10.
WataridaS., MoriA., OnoeM.. A clinical study on the effects of pulsatile cardiopulmonary bypass on the blood endotoxin levels.J Thorac Cardiovasc Surg1994; 108: 620–5.
11.
FumeroR., MontevecchiF.M., ScuriS., CarraraB., GambaA., ParenzanL.. Clinical experience with a new pulsatile pump for infant and pediatric cardiopulmonary bypass.Int J Artif Organs1989; 12: 314–20.
12.
ÜndarA., EichstaedtH.C., MasaiT.. Comparison of six pediatric cardiopulmonary bypass pumps during pulsatile and nonpulsatile perfusion.J Thorac Cardiovasc Surg2001; 122: 827–9.
13.
ÜndarA., EichstaedtH.C., BigleyJ.E.. Effects of pulsatile and nonpulsatile perfusion on cerebral hemodynamics investigated with a new pediatric pump.J Thorac Cardiovasc Surg2002; 124: 413–6.
14.
ÜndarA., KoenigK.M., FrazierO.H., FraserC.D.. Impact of membrane oxygenators on pulsatile versus nonpulsatile perfusion in a neonatal model.Perfusion2000; 15: 111–20.
15.
ÜndarA., LodgeA.J., DaggettC.W., RungeT.M., UngerleiderR.M., CalhoonJ.H.. The type of aortic cannula and membrane oxygenator affect the pulsatile waveform morphology produced by a neonate-infant cardiopulmonary bypass system in vivo.Artif Organs1998; 22: 681–6.