Abstract
Background
Perioperative management of post-infarction left ventricular free wall rupture (LVFWR) is not clearly standardized and surgical repair is the only therapeutic option. Role of off-pump surgery and stabilization with perioperative intraaortic balloon pumping (IABP) were here analysed.
Methods
Seven patients underwent surgery for LVFWR between 1990 and 2002. Clinical picture included electromechanical dissociation (3 patients) and sudden hypotension (4 patients). Except in one patient who was reanimated through femoro-femoral cardiopulmonary bypass, off-pump repair through on-lay patching technique was always performed. IABP was employed in the immediate postoperative period in five cases.
Results
A satisfactory hemodynamic state was restored in all cases and there were no reoperations for bleeding or rerupture. Hospital survival was 100%. One patient underwent successful surgical myocardial revascularization two months after LVFWR. Two patients died at follow-up. The survivors present with good NYHA and CCS functional classes.
Conclusions
When the anatomy of the LVFWR is favourable, off-pump external patching repair proves a good choice. Postoperative IABP provides satisfactory hemodynamic support.