Abstract
Purpose
To evalute whether the production of interleukin 2 (IL 2), interlukin 6 (IL 6) and interlukin 10 (IL 10) from stimulated peripheal blood mononuclear cells (PBMC) was affected by coating extracorporeal circuits in patients undergoing cardiopulmonary bypass (CPB). In addition, postoperative clinical parameters were compared between patients with heparin-coated and uncoated CPB.
Design
Prospective, controlled in vivo/ex vivo study.
Procedure
Blood samples were drawn immediately before, at the end and 24 hours after the end of CPB using either a conventional circuit (n=10) or a heparin-coated circuit (n=10) in patients undergoing CPB. Cytokine release on the supernatants of activated PBMC was detected. Cardiopulmonary parameters were measured before CPB, at ICU admission, 3 hours and 24 hours after ICU admission in both groups of patients. Statistical difference intragroups and between groups were investigated with the analysis of variance for repeated measures.
Results
IL 6 and IL 10 release was significantly less (p<0.05) in the heparin-coated group. No differences in clinical parameters were observed between the two groups.
Conclusions
These results suggest that with the use of heparin-coated circuits there is a lower production of IL 6 and IL 10 from isolated PBMC than with uncoated circuits.
Get full access to this article
View all access options for this article.