Bray RC, Dandy DJ: Comparison of arthroscopic and open techniques in carbon fiber reconstruction of the anterior cruciate ligament: Long-term follow-up after 5 years. Arthroscopy3: 106-110, 1987
2.
Charosky CB, Bullough PG, Wilson PD: Total hip replacement failures. J Bone Joint Surg55A: 49-58, 1973
3.
Crugnola A., Schiller LA, Radin E.: Polymeric debris in synovium after total joint replacement: Histological identification . J Bone Joint Surg59A: 860-862, 1977
4.
Deutman R., Mulder Th J, Bnan R., et al: Metal sensitivity before and after total hip arthroplasty J Bone Joint Surg59A: 862-865, 1977
Evans EM, Freeman Mar, Miller AJ, et al: Metal sensitivity as a cause of bone necrosis and loosening of the prosthesis in total joint replacement. J Bone Joint Surg56B: 626-642, 1974
7.
Kaufman RL, Tong I., Beardmore TD: Prosthetic synovitis: Clinical and histologic characteristics. J Rheum12: 1066-1074, 1985
8.
Kennedy JC, Roth JH, Mendenhall HV, et al: Presidential address: Intraarticular replacement In the anterior cruciate ligament-deficient knee Am J Sports Med8: 1-8, 1980
9.
Kennedy JC, Roth JH, Schmidt AA: The ligament augmentation device (LAD) in the anterior cruciate deficient knee. Orthop Trans4: 403, 1980
10.
Kitridou RC , Schumacher HR, Sbarbara JL, et al: Recurrent hemarthrosis after prosthetic knee arthroplasty: Identification of metal particles In the synovial fluid Arthritis Rheum12: 520-528, 1969
11.
Maguire JK, Coscia MF, Lynch MH: Foreign body reaction to polymeric debris following total hip arthroplasty . Clin Orthop216: 213-223, 1987
12.
McPherson GK , Mendenhall HV, Gibbons DF, et al: Expenmental mechanical and histological evaluation of the Kennedy ligament augmentation device. Clin Orthop196: 186-195, 1985
13.
Parsons JR, Bhayani S., Alexander H., et al: Carbon fiber debris within the synovial joint. Clin Orthop196: 71-76, 1985
14.
Revell PA, Weightman B., Freeman Mar, et al: The production and biology of polyethylene wear debris Arch Orthop Trauma Surg91: 167-181, 1978
15.
Rigdon RH Plastics and inflammation: An in vitro experimental study. J Biomed Mater Res8. 97-117, 1974
16.
Ritter MA: The Herbert total knee replacement A longer than three year follow-up . Clin Orthop129: 232-235, 1977
17.
Roth JH, Kennedy JC, Lockstadt H., et al: Polypropylene braid augmented and nonaugmented intraarticular anterior cruciate ligament reconstuction. Am J Sports Med13: 321-336, 1985
18.
Roth JH, Kennedy JC, McPherson GK, et al: Long term evaluation of the "ligament augmentation device" in the reconstruction of the anterior cruciate ligament in goats. Orthop Trans9: 156, 1985
19.
Rushton N., Dandy DJ, Naylor Cpe: The clinical, arthroscopic and histological findings after replacement of the anterior cruciate ligament with carbon-fibre J Bone Joint Surg65B: 308-309, 1983
20.
Smith RS, Atkinson RE, Jupiter JB: Silicone synovitis of the wrist. J Hand Surg10A: 47-60, 1985
21.
Strover AE, Firer P. The use of carbon fiber implants in anterior cruciate ligament surgery Clin Orthop196: 88-98, 1985
22.
Vernon-Roberts B., Freeman Mar: Morphological and analytical studies of the tissues adjacent to joint prostheses, in Engineering in Medicine New York, Springer-Verlag , 1976, pp 162-186
23.
Williams DF , Meachum G. A combined metallurgical and histological study of tissue-prosthesis interactions in orthopaedic patients J Biomed Mater Res5: 1-9, 1974
24.
Winter GD: Tissue reactions to metallic wear and corrosion products in human patients . J Biomed Mater Res5: 11-26, 1974